3 results found

Product brochure GEZE curved sliding door systems Slimdrive SC/SCR
Product brochure

doors GEZE SLIMDRIVE SC/SCR TABLE OF CONTENTS GEZE curved sliding door systems … Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR GEZE curved sliding door systems Innovative tailor-made entrance solutions The entrance area of a building reveals a building‘s character. Prestigious buildings all over the world are equipped with tailor-made entrance solutions from GEZE. Applications in different areas reflect our many years of experience. Curved sliding doors create more space and light. This range is characterised by ease of operation, a wide range of design options and straightforward installation. The advantages at a glance •• Individual planning and production for every building •• TÜV type-tested in accordance with DIN 18650 / EN 16005 in all versions •• Low drive height of … cm permits large passage heights and conveys an elegant appearance •• The high level of light creates bright, friendly entrance areas •• Emphasis on transparency with the glass roof variant •• High-quality materials and state-of-the-art control technology guarantee high efficiency •• Curved sliding doors create up to 40 % more opening width compared with linear sliding doors •• Just perfect for glass façades with slim post-rail-constructions •• Central suspension of the moving leaves guarantees very quiet running and a long service life •• FR variant for use in escape and rescue routes according to AutSchR •• Simple operation and adjustment based on tried-and-tested sliding door technology Slimdrive SC: drive for curved sliding doors, can be used as a vestibule in combination with linear sliding doors Slimdrive SCR: the 360° drive solution for curved sliding doors SC-FR and SCR-FR: approved for use in escape and rescue routes, type-tested in accordance with DIN 18650 / EN 16005 and certified Slimdrive SC/SCR GGS: version of the automated all-glass curved sliding doors with the all-glass fitting system GGS and glass roof Slimdrive SC RC … and SC-FR RC 2: the burglar-resistant curved sliding door system with fine-framed fitting system DIN 18650 The industrial standard DIN 18650 was created to be able to guarantee operators and users of automatic doors optimum safety. GEZE curved sliding door systems have been type-tested in accordance with DIN 18650 and certified. EN 16005 The new European standard EN 16005 sets out the design requirements and testing methods used to ensure the safe use of automatic doors. The new standard has created a Europe-wide safety standard for automatic doors. All automatic door systems and safety sensors from GEZE meet the EN 16005 standard and are available. Federal Foreign Office and European Integration, Zagreb, Croatia (Photo: Robert Les) … GEZE AUTOMATIC DOOR SYSTEMS Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Overview table of automatic curved sliding door systems Technical data Radius (max.) Moving leaf version Side elements version Surfaces Version of roof structure Illumination Floor covering Hot-air curtain system Off-centre façade connection Special functions on request Operation Approvals SC-FR SCR SCR-FR For escape and rescue routes Barrier-free Adjustable opening speed Adjustable closing speed Opening width 2-leaf Clear passage height* Canopy height (min.) Leaf weight (max.) 1-leaf Leaf weight (max.) 2-leaf Radius (min.) SC Product features ● ● ● ● ● ● ● ● ● ● ● ● ● ● 800 – 3000 mm 800 – 2300 mm 3000 mm 75 mm 100 kg 120 kg 1000 mm 1100 mm 1000 mm 1100 mm 2000 mm 10 mm VSG, 10 mm ESG-H with GGS fitting system (GGS variant), special glass on request 10 mm VSG, 22 mm panel lining, VSG 12 mm without frame (GGS variant), special glass on request Powder-coated according to RAL, anodised light alloy E6/EV1, colour anodised according to sample, coated with polished stainless steel, coated with grit 240 stainless steel, special coating on request Optical sheet metal covering, waterproof roof with waterspout, glass roof with roof variant, not possible with according to customer wishes, not glass roof possible with glass roof Scraper mat, floor mat according to customer wishes possible, depends on the ceiling integrated in the suspended ceiling construction ● ● ● ● ● ● ● ● Programme switch DPS Programme switch TPS Control via building management system DIN 18650, EN 16005 ● = YES - = NOT AVAILABLE * = HIGHER ON REQUEST Semi-circular and circular sliding door systems … Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR General product features for SC/SC-FR and SCR/SCR-FR System description •• •• •• •• •• •• •• Door profiles and running rail made of aluminium or with wood panelling Continuous floor guide made of stainless steel System can be designed convex (running inside) and concave (running outside) Individual solutions for side and upper connections to concrete, masonry, steel structure, glass structure as well as post-rail structure Large choice of surface finishes available System and moving leaf can be equipped fine-framed with GEZE profile systems or with the GEZE GGS fitting system There are numerous equipment versions for the design of the side elements and ceiling structure Version of FR variants suitable for use in escape and rescue routes •• Duplicate processing system thanks to 2-motor technology/rechargeable battery with a redundant control •• Programme switch is lockable: The programme switch may only be operated by authorised persons. For this reason, a key-operated switch is essential. The mode of operation selected must be able to be recognised clearly. •• Self-monitoring movement detector (redundancy): Function must be continually monitored. If a fault is diagnosed, the door moves to the open position (repairs necessary). •• Note on the locking of escape and rescue route doors (operation mode „night“): Automatic sliding doors for use in escape and rescue routes may be locked providing there are no escape and rescue route requirements made on them during this defined time period. This is usually the case when there is no-one in the building or if a different escape route is signposted for these people. Description of the control with functions •• •• •• •• •• •• •• •• •• •• •• •• •• Fully digital control with high-power micro-processor All system settings and display of function, error and maintenance parameters are possible via GEZE display programme switch Operating modes: automatic, permanently open, shop closing (one-way), night, off Reduced opening width with variable adjustment in learning mode, with the FR-version taking the minimum escape route width into consideration. This depends on the number of persons who will have to use this exit and is at least one metre from … GEZE AUTOMATIC DOOR SYSTEMS Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Overview of basic designs and special variants Curved sliding doors GEZE Slimdrive SC Basic design Special variant Special variant Double or multi-leaf curved sliding door, can be combined as required Reverse curve Set curved Special variant Special variant Special variant Vestibule 180° double-leaf curved sliding door combined with linear sliding door Corner door 90° maximum opening width with optimum use of space Corner door 270° double-leaf centrally opening or single-leaf outward opening Special variant Double entrance for separate entrance and exit Semi-circular and circular sliding door systems … Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Curved sliding doors GEZE Slimdrive SCR Basic design Special variant Special variant Vestibule 360° two double-leaf curved sliding doors, each 180°, with separate drives Extended to an oval, vestibule Enlarged vestibule Housing society Vieya, Dongen, Netherlands (Photo: Erwin Kamphuis) … GEZE AUTOMATIC DOOR SYSTEMS Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR GEZE Slimdrive SC Drive system for automatic curved sliding doors The GEZE Slimdrive SC conceals a powerful drive system for curved sliding doors in a unit only … cm high. The barrier-free drive blends in elegantly with post-rail-constructions and can be used in busy areas. Whether as a curved sliding door with a minimum radius of 1000 mm, as a curved sliding door with large radii or in combination with a linear sliding door as a vestibule: GEZE Slimdrive SC provides a huge range of design options and meets maximum function and design requirements. Opening widths of max. 3000 mm can be achieved for double-leaf doors with the Slimdrive SC. It moves leaf weights of up to a maximum of 120 kg. In the Slimdrive version SC-FR, the curved sliding door can also be used in escape and rescue routes (FR). Special versions Slimdrive SC GGS / SC-FR GGS - variant with automatic all-glass curved sliding doors with all-glass fitting system GGS and glass roof Slimdrive SC RC … Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Technical data Product features For escape and rescue routes Barrier-free Adjustable opening speed) Adjustable closing speed Opening width 2-leaf Clear passage height* Canopy height (min.) Leaf weight (max.) 1-leaf Leaf weight (max.) 2-leaf Radius (min.) Moving leaf version SC ● ● ● SC-FR ● ● ● ● 800 – 3000 mm 3000 mm 75 mm 100 kg 120 kg 1000 mm 1100 mm 10 mm VSG, special glass on request 10 mm VSG, 22 mm panel lining, special glass on request Powder-coated according to RAL, anodised light alloy E6/EV1, colour anodised according to sample, coated with polished stainless steel, coated with grit 240 stainless steel, special coating on request Optical sheet metal covering, waterproof roof with waterspout, glass roof with roof variant, not possible with glass roof Scraper mat, floor mat according to customer wishes possible, depends on the ceiling construction ● ● ● ● Programme switch DPS Programme switch TPS Control via building management system DIN 18650, EN 16005 Side elements version Surfaces Version of roof structure Illumination Floor covering Hot-air curtain system Off-centre façade connection Special functions on request Operation Approvals ● = YES - = NOT AVAILABLE * = HIGHER ON REQUEST Curved version Nominal radius (mm) System angle Passage angle System width (mm) 1000 1100 1200 1300 1400 2000 2200 2400 2600 Clear passage width (mm) 1144 1273 1401 Curve length (mm) 3142 3456 3770 10 GEZE AUTOMATIC DOOR SYSTEMS 1600 1700 1800 2800 1500 180° 80° 3000 3200 3400 3600 1530 1658 1787 1916 2044 2173 4084 4398 4712 5027 5341 5655 1900 2000 3800 4000 on on request request 5969 6283 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Standard dimensions Curve length BL = max. 5500 mm Passage width LW = 1000 mm - 2300 mm Vertical section KH Approximate calculation of the curve length = r B BL = B2 + 180 A B 16 … H BL DH x y · A x T2 = With radius r and angle y given = With overall depth T and system width B given DH = Passage height H = System height KH = Canopy height Horizontal sections B S y r S T B r LW BL LB B LB r S T = = = = = System width Passage clearance Nominal radius Inner width Overall depth B BL LB r S = = = = = System width Curve length Passage clearance Nominal radius Inner width Semi-circular and circular sliding door systems 11 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR GEZE Slimdrive SCR Drive system for automatic curved sliding doors The drive series GEZE Slimdrive SCR is the 360° drive solution for curved sliding doors. The drives of the two doors form one unit but are controlled separately. This drive for curved sliding doors can be integrated almost invisibly into the façade thanks to the extremely low overall height of only … cm. The state-of-the-art drive „disappears“ – leaving room for transparency and aesthetics. The SL SCR is barrier-free and just perfect for use in glass façades with a slim post-rail-construction. High-quality materials and state-of-the-art control technology ensure high efficiency. Opening widths of max. 2300 mm can be achieved for double-leaf doors with the Slimdrive SCR. It moves leaf weights of up to a maximum of 120 kg. In the Slimdrive version SCR-FR, the curved sliding door can also be used in escape and rescue routes (FR). Special versions Slimdrive SC RC … SGL Carbon, Meitingen, Germany (Photo: Dirk Wilhelmy) Application range •• •• •• •• •• •• •• •• Representative business premises Hotels and restaurants Hospitals Homes for the elderly and care homes Airports and railway stations Trade fairs, exhibitions and car showrooms Vestibule systems Suitable for new buildings, conversions and refurbishment thanks to the low overall height 12 GEZE AUTOMATIC DOOR SYSTEMS Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Technical data Product features For escape and rescue routes Barrier-free Adjustable opening speed (ventilation) Adjustable closing speed Opening width 2-leaf Clear passage height* Canopy height (min.) Leaf weight (max.) 1-leaf Leaf weight (max.) 2-leaf Radius (min.) Radius (max.) Moving leaf version SCR ● ● ● SCR-FR ● ● ● ● 800 – 2500 mm 3000 mm 75 mm 100 kg 120 kg 1000 mm 1100 mm 2000 mm 10 mm VSG, special glass on request 10 mm VSG, 22 mm panel lining, VSG 12 mm without frame (GGS variant), special glass on request Powder-coated according to RAL, anodised light alloy E6/EV1, colour anodised according to sample, coated with polished stainless steel, coated with grit 240 stainless steel, special coating on request Optical sheet metal covering, waterproof roof with waterspout, glass roof according to customer wishes, not possible with glass roof Scraper mat, floor mat according to customer wishes integrated in the suspended ceiling ● ● ● ● Programme switch DPS Programme switch TPS Control via building management system DIN 18650, EN 16005 Side elements version Surfaces Version of roof structure Illumination Floor covering Hot-air curtain system Off-centre façade connection Special functions on request Operation Approvals ● = YES - = NOT AVAILABLE * = HIGHER ON REQUEST Approximate calculation of the curve length Vertical section Horizontal section KH B S = r B BL = B2 + 180 16 … H BL DH x y · A r x T2 LW A B T = With radius r and angle y given = With overall depth T and system width B given = Overall depth DH = Passage height H = System height KH = Canopy height B LB r S = = = = System width Passage clearance Nominal radius Inner width Semi-circular and circular sliding door systems 13 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR GEZE Slimdrive SC/SCR GGS Elegance and transparency without frames The unpretentious and functional design of this stainless steel fitting opens up a wide range of individual application possibilities. The perfect design of curved sliding doors equipped with the GGS fitting system (GEZE all-glass system) is impressive. Maximum transparency is supported by the glass roof variant. The moving leaves are attached to the roller carriage using two single point fixings each and have been designed without frame. The floor guide is also attached to the glass with single point fixings. The side elements are made of curved laminated safety glass (VSG) and equipped with very slim profiles as edge protection. The SC/SCR GGS variant also allows a curved sliding door to be made from a combination of two curved sliding doors. The minimum radius is 1250 mm, the maximum clear passage is 2500 mm and the maximum leaf weight 100 kg. Deviations from these dimensions can be realised on request. The FR variant is available for use in escape and rescue routes. Application range •• •• •• •• •• •• •• •• Representative business premises Hotels and restaurants Hospitals Homes for the elderly and care homes Airports and railway stations Trade fairs, exhibitions and car showrooms Vestibule systems Suitable for new buildings, conversions and refurbishment thanks to the low overall height 14 GEZE AUTOMATIC DOOR SYSTEMS Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Technical data Side elements version Surfaces Version of roof structure Illumination Floor covering Hot-air curtain system Special functions on request Operation Approvals SC-FR GGS SCR GGS SCR-FR GGS For escape and rescue routes Barrier-free Adjustable opening speed (ventilation) Adjustable closing speed Opening width 2-leaf Clear passage height* Canopy height (min.) Leaf weight (max.) 1-leaf Leaf weight (max.) 2-leaf Radius (min.) Radius (max.) Moving leaf version SC GGS Product features ● ● ● ● ● ● ● ● ● ● ● ● ● ● 800 – 3000 mm 800 – 2300 mm 2500 mm 75 mm 100 kg 120 kg 1250 mm 2000 mm 10 mm ESG-H with GGS fitting system (GGS variant), special glass on request VSG 10 mm without frame (GGS variant), special glass on request Powder-coated according to RAL, anodised light alloy E6/EV1, colour anodised according to sample, coated with polished stainless steel, coated with grit 240 stainless steel, special coating on request Optical sheet metal covering, waterproof roof with waterspout, glass roof with roof variant, not possible with glass roof Scraper mat possible, depends on the ceiling construction ● ● ● ● Programme switch DPS Programme switch TPS Control via building management system DIN 18650, EN 16005 ● = YES - = NOT AVAILABLE * = HIGHER ON REQUEST Semi-circular and circular sliding door systems 15 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR GEZE Slimdrive SC/SC-FR RC … class such as screwdrivers, pliers and wedges, and can withstand static and dynamic loads. Opportunists are stopped effectively and security companies gain reaction time. SGL, Carbon, Meitingen, Germany (Photo: Dirk Wilhelmy) Application range •• •• •• •• •• •• Building entrances with enhanced safety requirements Banks Pharmacies Jewellers Petrol stations IT rooms 16 GEZE AUTOMATIC DOOR SYSTEMS Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Technical data Product features For escape and rescue routes Barrier-free Adjustable opening speed (ventilation) Adjustable closing speed Opening width 2-leaf Clear passage height Canopy height (min.) Leaf weight (max.) 2-leaf Radius (min.) Moving leaf version Side elements version Surfaces Version of roof structure Illumination Floor covering Hot-air curtain system Special functions on request Operation Approvals SC/SC-FR RC … is only enabled in „NIGHT“ mode. In „NIGHT“ mode the door does not fulfil any emergency exit requirements. It is necessary to ensure that there is nobody in the building or that sufficient other emergency exits are available. Semi-circular and circular sliding door systems 17 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Operating automatic sliding doors Programme switch for selecting the mode of operation of automatic sliding doors GEZE offers programme switches for a wide range of individual requirements. The switches are suitable for universal use – for surface-mounted or flush-mounted installation. The following switches are available: Display programme switch (DPS) Key programme switch (TPS) The following operating modes can be set: “Permanently open” The door moves to the OPEN position and remains open. Movement detector or opening button are deactivated. “Night” The movement detectors are switched inactive, the door closes. The door can only be opened with contact sensor authorised (KB) or manual release. Option: The door leaves are locked electrically to prevent forced opening. “Shop closing” (One-direction operation from the inside to the outside) The door only opens and closes when someone goes out from the inside. The movement detector outside is switched inactive, the one inside is switched active. “Automatic” The door opens as soon as it is actuated via the movement detector or keys, and closes after a certain individually adjustable time. Safety sensors protect the leaves’ travel path. If there is someone in the door opening, the door will not close. “OFF” (depending on model) Drive motor, locking, activationand safety sensors are switched off, the door leaves can be moved manually. Key switch The programme switch can be blocked using a key switch. A key switch is required for the F/R variants. Securing the programme switches The display programme switch (DPS) and key programme switch (TPS) can be combined with a key switch. Alternatively, these programme switches can be secured using a code. Display programme switch (DPS) 18 Keypad programme switch (TPS) GEZE AUTOMATIC DOOR SYSTEMS Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Securing automatic sliding doors Sensor package for SC systems … 4 Optional: GC 363 rain cover to protect the combined detector / light curtain outdoors Combined detectors GC 363 R and GC 363 SF (in direction of emergency exit) for triggering and securing the automatic door Light curtain GC 339 for protecting the opening width Optional: GC 363 ceiling installation kit for integrating the combined detector/light curtain in the ceiling Semi-circular and circular sliding door systems 19 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Automatic locking Locking by toothed belt This electromagnetic bi-stable locking system ensures more safety, because it stays locked even without electric current. Manual emergency unlocking is possible at any time. Typical for this type of locking is permanent monitoring by the control unit. Up to two contacts for external applications (e.g. alarm systems) can be integrated as an option. Thanks to the free choice of positioning in the drive, the toothed belt unit is not only easy to install, it also makes special locking functions possible, e.g. locked pharmacy opening of the sliding doors. Rod locking Rod locking increases safety and burglary protection. The multi-point lock – both upwards and in the ground – provides solid resistance against attempts to be levered open. The locking rod is integrated invisibly in the fine-framed ISO profile system. The system can be unlocked both electrically or mechanically. Manual locking Floor lock The GEZE floor lock is used to lock door leaves with the fine-framed ISO profile system easily at floor level. Standard profile cylinders can be used for the floor locks. This means the solution is suitable for optimum integration in locking systems. Operation is manual, with the key, either only from the inside or from the inside and outside. Floor lock 20 GEZE AUTOMATIC DOOR SYSTEMS Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Service Tools GEZEconnects Bluetooth is an internationally standardised short-distance radio signal with a range of up to ten metres. The software GEZEconnects makes wireless connection via Bluetooth possible between a computer and the automatic door systems from GEZE. All door system settings can be carried out via an intuitive graphic interface, stored, sent by e-mail and transferred to a word processing programme as a protocol. Diagnosis functions show the most important function parameters of the door system in real time, so that problems are recognised at a glance and can be eliminated. All the pre-settings can be taken over very easily for further door systems. The convenient documentation of initial operation, servicing and diagnosis protocols as well as all statistical data can be downloaded at any time. Password protection to freeze operating parameters and servicing data guarantees there will be no unauthorised modifications made. Service terminal ST 220 Mobile, handy and straightforward – that is parameter setting for the automatic GEZE door systems using the service terminal ST 220. Communication and data exchange between the service terminal and the door drive is via an integrated RS485 interface. The large illuminated interface is easy to operate thanks to the plain text display. The service terminal is equipped with a readout function for servicing and diagnosis work. Power is supplied via the door system. Password protection to freeze operating parameters and servicing data guarantees there will be no unauthorised modifications made. GEZEconnects I SOFTW ARE zur kabellosenVerbindung von GEZE AutomatischenTürsystemen und PCs über Bluetooth GEZEconnects I SOFTW ARE TÜRTECHNIK AUTOMATISCHE TÜRSYSTEME GEZE GmbH Reinhold-Vöster-Str. 21-29 71229 Leonberg Germany Telefon: +49 (0)7152-203-0 Telefax: +49 (0)7152-203-310 www.geze.com RWA UND LÜFTUNGSTECHNIK Systemvoraussetzungen: PC mit Windows XP Intel oder 100% kompatiblen Prozessor 500 MB RAM 1,5 GHz CD Laufwerk Bluetooth Schnittstelle 150 MB freier Speicherplatz GEZEconnects I SOFTW ARE zur kabellosenVerbindung von GEZE AutomatischenTürsystemen und PCs über Bluetooth SICHERHEITSTECHNIK GLASSYSTEME Id.Nr. 134995 · Version 090518 · Änderungen vorbehalten B EW E G U N G M I T S Y S T E M B EW E G U N G M I T S Y S T E M GEZEconnects Service terminal ST 220 Semi-circular and circular sliding door systems 21 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Installation drawings SC/SCR Slimdrive SC(-FR) and SCR(-FR) A … Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Hot-air curtain in ceiling canopy … 6 = = = = = = Supply lines for hot-air curtains on site Opening for hot-air curtain line routing Suspended ceiling with preparatory work for hot-air curtain system Hot-air curtain system Air intake Air blow-out Semi-circular and circular sliding door systems 23 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Floor ring … Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Façade connection with sheet metal panel min. 40 mm … 4 = = = = Sealing on site Optional: Façade connection (panel) Sheet aluminium weather guard, chamfered Minimum distance: 40 mm, due to mounting Semi-circular and circular sliding door systems 25 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Cable plan Slimdrive SL-SC For detailled information concerning connection of the activationdevices and sensors refer to connection diagram 148583 (English version). 230V / 50Hz power supply cable 400V / 50Hz power supply cable For draught lobby operation with 2nd drive 230V / 50Hz power supply cable 10 A fuse (provided by customer) … 1 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR References Cafe Luitpold, Munich, Germany (Photo: Robert Sprang) Hippauf & Stegmüller, Arnstorf, Germany (Photo: Robert Sprang) Semi-circular and circular sliding door systems 27 Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Referenzen Beaufort House, London, UK (Photo: Michael Molloy Photography Ltd) Hotel Schloss Elmau Retreat, Elmau, Germany (Photo: Robert Sprang) 28 GEZE AUTOMATIC DOOR SYSTEMS Automatic semi-circular and circular sliding doors GEZE SLIMDRIVE SC/SCR Referenzen CEMAG Anlagenbau, Hameln, Germany (Photo: Lothar Wels) Casino, Monte-Carlo, Monaco (Photo: Jean-Louis Martinetti) Semi-circular and circular sliding door systems 29 Innovative system solutions POTENTIAL APPLICATIONS OF GEZE PRODUCTS You will find more product information in the relevant brochures, see ID numbers. Door technology 01 02 03 04 05 Overhead door closers ID 091593, ID 091594 Hold-open systems ID 091593, ID 091594 Integrated door closers ID 091609 Floor springs and all-glass fittings ID 091607 Sliding fitting systems and linear guides 13 ID 123605, ID 000586 04 Automatic door systems 06 07 08 09 10 Swing doors 11 ID 144785 01 Sliding, telescopic and folding doors 02 ID 143639 22 Curved sliding doors 06 ID 135772 17 06 Revolving doors ID 132050 11 Activation devices and sensors ID 142655 04 Smoke and heat extraction and window technology 11 12 13 14 15 Fanlight opening systems ID 127787 Electric opening and locking systems ID 127785, ID 127789 Electrical spindle and linear drives ID 127785, ID 127789 Electric chain drives ID 127785, ID 127789 17 18 19 20 ID 127785, ID 139075 Emergency exit systems ID 132408 Access control systems ID 132158 Panic locks ID 132848 Electric strikes ID 148666 Building management system ID 132408 Glass systems 21 22 30 20 14 Manual sliding wall systems (MSW) ID 104377 Integrated all-glass systems (IGG) ID 104366 GEZE AUTOMATIC DOOR SYSTEMS 07 10 Smoke and heat extraction systems Safety technology 16 08 07 Innovative system solutions POTENTIAL APPLICATIONS OF GEZE PRODUCTS Door technology The functionality, superior performance and reliability of GEZE door closers are impressive. A common design across the range, the ability to use them on all common door leaf widths and weights, and the fact that they can be individually adjusted makes their selection simple. They are continually being improved and enhanced with up-to-date features. For example, the requirements of fire protection and accessibility are fulfilled with a door closer system. Automatic door systems 15 GEZE automatic door systems open up a huge variety of options in door design. The latest, innovative highperformance drive technology, safety, ease of accessibility and first class universal drive design set them apart. GEZE offers complete solutions for individual requirements. 17 Smoke and heat extraction and window technology 21 GEZE smoke and heat extraction systems and ventilation technology provide complete systems solutions combining the many requirements of different types of windows. We supply a full range from energy efficient drive systems to natural ventilation and complete solutions for supplying and extracting air, also as certified SHEVs. 15 05 12 03 Safety technology GEZE safety technology sets the standards where preventative fire protection, access control and anti-theft security in emergency exits are concerned. For each of these objectives GEZE offers tailored solutions, which combine the individual safety requirements in one intelligent system and close doors and windows in case of danger in a coordinated manner. 21 18 Building systems 16 09 19 In GEZE’s Building Management System GEZE door, window and safety products can be integrated in to the security and control systems of the building. A central control and visualisation system monitors various automation components in the building and offers security through many different networking capabilities. Glass systems GEZE glass systems stand for open and transparent interior design. They can either blend discreetly into the architecture of the building or stand out as an accentuated feature. GEZE offers a wide variety of technologies for functional, reliable and aesthetic sliding wall or sliding door systems providing security with lots of design scope. Semi-circular and circular sliding door systems 31 G E Z E AU TO M AT I C D O O R S Y S T E M S GEZE GmbH P.O. Box 1363 71226 Leonberg Germany GEZE GmbH Reinhold-Vöster-Straße 21-29 71229 Leonberg Germany Telefon +49 7152 203

Product brochure Apoll roller sliding fitting system
Product brochure

DOORS, END-FOLDING AND CENTRE-FOLDING DOORS B E W E G UN G M I T S YS T EM Photo on page 2: Siegelwerk GmbH Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM CONTENTS GEZE Apoll – The roller guided sliding fitting system for particularly heavy industrial doors Apoll for sliding doors Apoll for folding doors Apoll für centre-folding doors Apoll accessories for end-folding and centre-folding sliding doors Product information for sliding fitting systems … Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE APOLL The roller guided sliding fitting system for particularly heavy industrial doors Apoll, the largest roller sliding fitting from GEZE, can be used to implement all heavy sliding door systems, such as, car park sliding gates. Apoll has already proved itself to be successful in conveyor and moving systems and as mounting aids in trade and industry. The sendzimir galvanisation of the steel running rail and the other parts ensure high protection from corrosion. Product features For door leaves elements with up to 600 kg Suitable for all sliding doors and door materials Wall and floor installation Durable solutions with single and double roller carriages No contamination due to the closed runner Prismatic running rail ensure optimal operation Hardened steel rollers, ball bearing mounted Ball bearing mounted plastic rollers for particularly quiet operation Movable hanger available in three strengths Individual radii for running rails available on request. Designs: Single or double roller carriage with steel or plastic rollers j j j j j j j j j j j Standard version/Scope of delivery: Steel, sendzimir galvanised running rails All other parts galvanised j j … GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Size 0,1,2 Product features Enclosed tubular track Prismatic troughs Tempered rollers with ball bearings Movable hangers … sizes j j j j j Range of applications For all sliding doors For all door materials For wall and ceiling installation For conveying and shifting systems As mounting aids for trade and industrial applications For heavy loads, see table j j j j j j Load-bearing capacity of track with 700 mm bracket spacing: Size … Fig. 05-1 GEZE Apoll Number of rollers Material of rollers Permissible door weight of sliding doors Roller load of conveyors *) Size … Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors Application methods When installing a sliding door, it is essential that stability and static and dynamic equilibrium are assured. The height-to-width ratio, and the resulting different hanging points and fittings, such as door plates or edge-fixing hangers, is therefore decisive. At a width-to-height ratio greater than 1, it is recommended to move the hanging point … x W towards the middle of the door (picture 1). At a width-to-height ratio less than 1, it is best to select edge-fixing hangers, -41, especially for very narrow doors (picture 2). With 2-leaf or multi-leaf door units, edge-fixing hangers, -42, which prevent the rollers from colliding, should be used (picture 3). The end stop -3 (picture 5) is not intended for door stopping, but only as a mounting aid and safety device when installing the sliding door. When the door is in service a wall-fixed door stop, -66, must be positioned at the centre of gravity of the door to stop it. Two wall-fixed stops, -66, are also possible (picture 4). Door stops centered or at … points. The flat-plate guide roller, -50, can be used for all door guides, irrespective of which overhead hanger is selected. However, an edge-fixing guide roller, -51, -52, will be stronger (picture 6). With straight-in opening sliding doors the position of the floor guides is independent of the fixing point of the overhead hangers. … GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Installation options … Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Installation options Side and ceiling installation for double console on soft mounting surfaces bolt in steel plate 0-22 1-22 0-22 1-22 Size … 45 65 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Installation options … Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Tracks Track Size … 2,5 3,5 kg (weight) 2,85 4,53 12,4 straight length 1500 1660 2170 ID No. 054771 054773 ID No. (6m) Track curve Fig. 10-2 10 GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS 054769 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Brackets Wall installation bracket Fig. 11-1 Size … ID No. 024126 013097 007197 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Consoles for vertical and lateral adjustment with bracket for vertical and lateral adjustment: 0-14, 1-14, 2-14 Single consoles for lateral and vertical adjustment wall installation ceiling installation Fig. 13-1 Size … g 50 70 m M 10 M 12 f 20,5 26,5 Adjustment range c 69 85 kg (weight) 0,4 0,8 ID No. 024402 013997 Manual sliding door systems 13 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Rollers Single roller, steel or plastic Fig. 14-1 Size … d = yes, s = no Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Rollers with pivot bearing Single roller with pivot bearing Fig. 15-1 Size … Des. 0-33 1-33 2-33 a 50 65 85 b 35 48 68 l 100 150 190 m 80 114 140 h 32 42 56 c 26 37 48 e 32 42 56 d M 10 M 12 M 16 n 13 20 25 h1 60-83 83-101 126-129 kg (weight) 0,57 1,28 2,8 Load max. 100 kg max. 200 kg max. 300 kg ID No. 050997 049950 049962 Manual sliding door systems 15 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Door plates and edge-fixing hangers Door plate Size … 6 kg (weight) 0,2 0,5 ID No. 019019 012663 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Floor guide rollers and floor channel Flat-plate guide rollers Size … 6 kg (weight) 0,2 0,5 ID No. 020522 021672 Fig. 17-2 Manual sliding door systems 17 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for sliding doors – Curved floor channel and accessories Curved floor channel Size … 6 kg (weight) 0,15 0,36 ID No. 000339 000342 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM ORDERING INFORMATION – GEZE APOLL FOR SLIDING DOORS Description Track, galvanized steel Track curve, galvanized steel Curve 900 bearing length … 018014 051472 s s s 054771 s 054773 007371 s s 024689 014440 020701 023286 024004 024093 024126 024325 024402 012686 012691 012694 012697 013097 013772 013997 011554 012119 012306 016268 054045 017274 054046 050996 050997 050998 012468 054050 012651 054051 051021 049950 049951 008426 -40 0-41 0-42 1-41 1-42 0-43 1-43/1 1-43/2 018431 018801 019019 012658 010890 s s s s s s -50 0-51 0-52 1-51 1-52 -54 -54 0-55 1-55 2-55 -66 -10 -11 -12 -13 -14 -20 -21 -21 -30 -36 -31 -37 -32 -33 -34 s 007197 s s s 009484 s 049961 049962 049963 s 012661 012663 019138 s s s 012947 012946 s 019884 020404 020522 012665 011139 s s s s s 012670 012672 051649 051650 s s s 051649 051650 054770 s s s 051654 051655 s s s 054772 s s s 054774 000339 000339 000342 = yes, s = no For sliding doors with curved track the rollers with pivot bearings should be used. Manual sliding door systems 19 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding doors – Size 0,1,2 The leaves fold out only in one direction. Because of the eccentric load when the door is folded, a bottom guide roller is essential. There are three common fitting options: Butt surface-mounted Butt flush-mounted Rebate-mounted. j j j The roller forms the pivot point on the front face of every second leaf. A full-height swing leaf is only possible with an odd number of leaves. The most usual form of track mountingis by wall or ceiling installation brackets. Flush bolts should be fitted to the fold-out side. The floor guide rollers should be fitted plump underneath the pivot point of the rollers. The best leaf widths are between 600 mm and 900 mm. Use … hinges per leaf; for high leaves (≥ 280 cm) 4. Hinges with ball bearings are recommended. Starting with the end leaf hinged to the jamb, every second leaf is fitted with a roller with pivot bearing and edge-fitting hanger. When choosing the track size and the roller, it should be noted that each roller has to take approximately the weight of two leaves. The use of double rollers is recommended. In the fold area the brackets for track mounting should be spaced at 350 mm (increased load-bearing). 20 GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS Fig. 20-1 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding doors – Size 0,1,2 0-10 1-10 2-10 0-35 1-35 0-42 1-42 0-1 1-1 0-33 1-33 0-11 1-11 0-1 1-1 0-44 1-44 0-65 1-65 0-52 1-52 2-52 0-53 1-53 1-54 Execution … h3 29 38 48,5 u 110 180 220 h4 43,5 55,5 72,5 v 20 20 30 h5 15 18 24,5 w 35 45 53 Manual sliding door systems 21 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding doors – Size 0,1,2 0-32 1-32 2-32 0-14 1-14 2-14 0-1 1-1 0-20 1-20 2-20 0-41 1-41 2-41 The gaps between the individual leaves when closed up are not taken into account in calculating the leaf width. The leaf width should be adjusted according to choise of gap width. locking device by customers 0-51 1-51 2-51 a = leaf width, leaf hinged to jamb a1 = a + (c+d+n1) a1 = a2 = a3 ... an leaf width of following leaves a1 = a = a1-(c+d+n1) B+(c+d+n1) z+1 b = leaf thickness a = B-(a1 * z) c = 1/2 hinges ø+1 B = a+a1+a2+a3 ... an d = b/2 B = a + (a1 * z) z = number of leaves n1 = 18 with size … u 110 180 220 w 35 45 53 x 14 20 30 y 20,5 26,5 35 GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding doors – Installation options Installation options and examples for folding doors For folding doors there are three different methods of fitting: Mounting option for folding doors: Butt surface-mounted Butt surface-mounted Butt surface-mounted, wall mounting with wall installation bracket -10, track -1, double roller with pivot bearing -33, edge-fixing hanger for folding doors -44, edge-fixing guide roller for folding doors -53 and flush bolt -65, floor channel -54. Butt surface-mounted folding door a1 = a2 = a3 = leaf width b = leaf thickness c = 1/2 hinge roller ø+1 Only possible with odd number of leaves. Size … Edge-fixing hanger 0-44 1-44 2-44 Edge-fixing guide roller 0-53 1-53 2-53 Dim. f 25 32 39,5 Dim. 20,5 26,5 35 Fig. 23-1 Mounting option for folding doors: Butt flush-mounted Butt flush-mounted Butt flush-mounted, soffit mounting with ceiling installation bracket -11, track -1, double roller with pivot bearing -33, edgefixing hanger -41, floor guide roller -51 and flush bolt -65, floor channel -54. Butt flush-mounted folding door b/2 = half door thickness c = 1/2 hinge roller ø+1 a1 + a2 = leaf width a = leaf width - (n+b/2+c) Size … Edge-fixing hanger 0-41 1-41 2-41 Floor guide The leaf fitted at the blind frame is smaller than leaf a by the dimension (n+b/2+c) 0-51 Dim. n 18 1-51 2-51 20 30 Removable cover Fig. 23-2 Manual sliding door systems 23 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding doors – Installation options Mounting option for folding doors: Rebate-mounted Rebate-mounted folding door a1 = a2 = a3 = leaf width b = leaf thickness c = 1/2 hinge roller ø+1 Rebate-mounted Rebate-mounted, wall mounting with wall installation bracket -10, track -1, double roller with pivot bearing -33, edge-fixing hanger for end-folding doors -44, edge-fixing guide roller for folding doors -53 and flush bolt -65, floor channel -54. Only possible with odd number of leaves. Size … Edge-fixing hanger 0-44 1-44 2-44 Edge-fixing guide roller 1-53 2-53 Dim. f 25 0-53 32 39,5 Dim. 26,5 35 20,5 Fig. 24-1 STANDARD DRAWINGS FOR FOLDING DOORS Drawing Wall and ceiling installation GEZE Apoll Size … ID No. 10620/0-10 10621/0-10 10621/0-11 10621/0-12 10622/0-12 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM ORDERING INFORMATION – GEZE APOLL FOR FOLDING DOORS Summary of fittings Fitting No. ID No. Size … edge-fixing hanger for folding doors pivot point 118 mm pivot point 160 mm … edge-fixing guide roller for folding doors … floor channel for folding doors, cut to size (length as track) 82 x 35 mm … leaves d = yes, s = no Summary of fittings 4-leaf folding door, see next page Manual sliding door systems 25 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM ORDERING INFORMATION – GEZE APOLL FOR FOLDING DOORS Summary of fittings Fitting No. ID No. Size … dge-fixing hangers for folding doors pivot point 118 mm pivot point 160 mm … edge-fixing guide rollers for folding doors … edge-fixing guide rollers d pivot point 160 mm pivot point 190 mm pivot point 160 mm pivot point 190 mm pivot point 90 mm 0-42 1-42 0-52 1-52 1-52 019019 s s s 012663 s 020522 s s s 012672 012672 s s = yes, s = no Ordering information GEZE Apoll folding door gear size ... number of leaves ... folding to right (left) , wall installation (or ceiling installation) ... block frame clearance height and width (H, B) 26 GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS s Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for centre-folding doors – Size 0,1,2 Centre-folding, i. e. half inward and half outward. Centre-folding doors start with a half leaf hinged to the jamb. The rollers are fitted above the centre of the leaf. The first roller is normally positioned at the first full leaf. The track can be mounted with soffit- oder wall installation brackets. On the underside of each leaf, on the side towards which the leaf folds, a flush bolt is fitted. The floor guide should be arranged plumb underneath the roller carriage. The best leaf widths are between 600 mm and 900 mm. Fig. 27-1 Use … hinges per leaf; for high leaves (≥ 280 cm) 4. Hinges with ball bearings are recommended. The first leaf is fitted with a roller; thereafter every second leaf. When choosing the track size and the roller, it should be noted that each roller has to take approximately the weight of two leaves. The use of double rollers is recommended. In the fold area the brackets for track mounting should be spaced at 350 mm (increased load-bearing). Manual sliding door systems 27 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for centre-folding doors – Installation options 0-40 1-40 2-40 0-33 1-33 2-33 0-40 1-40 2-40 0-35 1-35 2-35 0-1 1-1 2-1 0-10 1-10 2-10 0-11 1-11 2-11 0-65 1-65 0-54 1-54 0-50 1-50 2-50 0-50 1-50 2-50 by customers The gaps between the individual leaves when closed up are not taken into account in calculating the leaf width. The leaf width should be adjusted according to choise of gap width. a = first leaf B = clearance width a = a2 = a3 ... an leaf width of following leaves a = B - (z * a1) a = a1 / … h3 29 38 48,5 u 110 180 220 h4 43,5 55,5 72,5 v 20 20 30 h5 15 18 24,5 w 35 45 53 GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for centre-folding doors – Installation options 0-32 1-32 2-32 0-14 1-14 2-14 Size … u 110 180 220 w 35 45 53 x 14 20 30 y 20,5 26,5 35 0-20 1-20 2-20 0-40 1-40 2-40 0-50 1-50 2-50 Fig. 29-1 STANDARD DRAWINGS FOR CENTRE-FOLDING DOORS Drawing Wall and ceiling installation GEZE Apoll Size … ID No. 10620/0-20 10621/0-20 10622/0-20 10621/0-21 10622/0-21 Manual sliding door systems 29 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for centre-folding doors – Installation options Size … 1-40 2-40 1-50 2-50 Door plate 0-40 Floor guide roller 0-50 a1 = a2 = a3 ... an width of following leaves a = width of the first leaf to blind frame Fig. 30-1 Ceiling installation Ceiling installation With single console -20, bracket for vertical and lateral adjustment -14, track -1, double roller with pivot bearing -33, door plate -40, flat-plate guide roller -50, flush bolt -65, floor channel -54. With ceiling installation bracket -11, track -1, double roller with pivot bearing -33, door plate -40, flat-plate guide roller -50, flush bolt -65, floor channel -54. Fig. 30-2 Wall installation Wall installation With single console -20, bracket for vertical and lateral adjustment -14, track -1, double roller with pivot bearing -33, door plate -40, flat-plate guide roller -50, flush bolt -65, door channel -54. With wall installation bracket -10, track -1, double roller with pivot bearing -33, door plate -40, flat-plate guide roller -50, flush bolt -65, door channel -54. Fig. 30-3 30 GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM ORDERING INFORMATION – GEZE APOLL FOR CENTRE-FOLDING DOORS Summary of fittings Fitting No. ID No. Size … 1/2-leaf centre-folding doors: … 1/2-leaf centre-folding door fitting systems, see next page Manual sliding door systems 31 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM ORDERING INFORMATION – GEZE APOLL FOR CENTRE-FOLDING DOORS Summary of fittings Fitting No. ID No. Size … (+1/2 leaf per folding side), Folding to right (left), block frame clearance height and weight (H, B) Wall installation (or ceiling installation) 32 s GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS s 007197 049962 s 049961 010890 011139 051655 s Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for end-folding and centre-folding doors – Accessories Single roller with pivot bearing Fig. 33-1 Size … b 22 25 30 h 66-83 83-101 106-129 kg (weight) 0,07 0,08 0,1 ID No. 050998 049951 049963 Double roller with pivot bearing Fig. 33-2 Pivot bearings, loose Fig. 33-3 Manual sliding door systems 33 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding and centre-folding doors – Accessories Double roller with pivot bearing, reduced version Fig. 34-1 34 GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS Size … Des. 0-35 1-35 Door thickness < 40 < 60 a 50 65 b 35 48 m 34 45 h 58 80 e 32 42 d M 10 M 12 n 13 20 h1 66-83 83-101 kg (weight) 0,35 0,9 Load max. 100 kg max. 200 kg ID No. 054044 054052 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding and centre-folding doors – Accessories Edge-fixing hanger, pivot point 18, 20, 30 mm Size … Fig. 35-2 Edge-fixing hanger for folding doors Fig. 35-3 Des. 0-44 1-44 a 110 180 b 147 225 c 22 30 s … 6 kg (weight) 0,25 0,6 ID No. 050994 051012 Manual sliding door systems 35 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding and centre-folding doors – Accessories Door plate Size … kg (weight) 0,11 0,3 0,5 ID No. 019884 012665 011139 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding and centre-folding doors – Accessories Edge-fixing guide roller for folding doors Fig. 37-1 Size … 6 kg (weight) 0,2 0,5 ID No. 020522 012672 Fig. 37-3 Manual sliding door systems 37 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM GEZE Apoll for folding and centre-folding doors – Accessories Flush bolt size … of the “Produkthaftungsgesetz” (German Manufacturer’s Liability Law), the following information on sliding door gear should be observed. Failure to do so absolves the manufacturer from liability. Product information and use in accordance with intended purpose Sliding door gear, according to this definition, are fittings for doors and other push-able elements, henceforth called objects, which are not normally moved faster than walking pace. Sliding door gear is used in vertically fitted doors made of wood, plastic, glass, aluminium or steel and appropriate combinations of these materials. A floor guide is provided at the lower horizontal edge of the door. Special versions of products must be specified for damp rooms, direct exposure to the elements, exposure to cross winds, for installation near the sea and in highly corrosive conditions. Correct installation by qualified personnel is a particularly important aspect of use for intended purpose. The object must be sufficiently rigid at all of these points. The function of the gear must not be hindered or altered by installation. A buffer must be used in order to limit the displacement path. Misuse Misuse - in other words use in a manner not in accordance with the intended purpose - can be said to occur in the following cases in particular: j j j j j j j j j j if the gear is used with a higher max. load than specified in the catalogue and in the other product documents, if incorrectly installed or attached, if ambient temperatures are too high or too low, if particularly aggressive media can affect the gear, if subjected to inordinately great pushing or pulling loads, if the position of the track deviates too greatly from the horizontal, if foreign bodies get into the track, if the rollers are operated too fast, if alterations are carried out without the manufacturer’s authorization, if obstacles are placed in the opening or between the door or the object thereby preventing intended use, if additional loads act upon the door or object, if someone is trapped between the door and the door frame while the door is being pushed or closed, or if a person or part of the body is in this area. Product Maintenance Components of sliding door gear which are relevant to safety must be regulary inspected for proper fixing and signs of wear. Fixing screws are to be re-thightened and faulty components must be replaced. In addition, the following maintenance work must be carried out at least once a year: j j j j j All moving parts are to be tested for free movement. In the case of running carriages with metal rollers, the moving parts must be greased (type of grease to be used on request). Plastic rollers must not be greased. Only use cleaning agents which do not impair the anti-corrosion protection of the gear. Faulty sliding door gears must be replaced. Adjustment work on the gears and the replacement must be carried out by qualified personnel. Duty of Information and Instructions The following sources of information are available to planners, specialist dealers, administrative personnel, building contractors and users by way of fulfillment of the duty of information and instruction: j j j j catalogues, brochures descriptions of tender, descriptions of offer mounting drawings, installation drawings maintenance and operating instructions. In order to ensure correct use, proper functioning and maintenance and care of sliding door gear, j j j architects and planners must request and apply the necessary product information, specialist dealers must take account of the product information and notes in the price lists, and in particular must request all necessary instructions and pass these on to the installation personnel, installation personnel must take account of all product information, and in particular must request operating and maintenance instructions and pass these on to the ordering party and the user. Application for similar fittings Sliding fittings with horizontally installed objects, e.g., drawer guides or sliding fittings with vertical runner tracks must be handled according to their respective characteristics with respect to product information, use for intended purpose, misuse, product performance, Product Performance product maintenance and servicing, and duty of information and In cases where the performance of the product is not specifically instruction. described in the catalogues, brochures, instructions etc., special requirements must be discussed with and agreed by the manufacturer. Our regulations, which affect the composition of the sliding door gear, are binding. j j Manual sliding door systems 39 Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM NOTES 40 GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS Manual sliding door systems GEZE APOLL ROLLER GUIDED SLIDING FITTING SYSTEM NOTES Manual sliding door systems 41 Innovative system solutions POTENTIAL APPLICATIONS OF GEZE PRODUCTS You will find more product information in the relevant brochures, see ID numbers. Door technology 01 02 03 04 05 Overhead door closers ID 091593, ID 091594 Hold-open systems ID 091593, ID 091594 Integrated door closers ID 091609 Floor springs and all-glass fittings ID 091607 Sliding fitting systems and linear guides 13 ID 123605, ID 000586 04 Automatic door systems 06 07 08 09 10 Swing doors 11 ID 144785 01 Sliding, telescopic and folding doors 02 ID 143639 22 Curved sliding doors 06 ID 135772 17 06 Revolving doors ID 132050 11 Activation devices and sensors ID 142655 04 Smoke and heat extraction and window technology 11 12 13 14 15 Fanlight opening systems ID 127787 Electric opening and locking systems ID 127785, ID 127789 Electrical spindle and linear drives ID 127785, ID 127789 Electric chain drives ID 127785, ID 127789 17 18 19 20 ID 127785, ID 139075 Emergency exit systems ID 132408 Access control systems ID 132158 Panic locks ID 132848 Electric strikes ID 148666 Building management system ID 132408 Glass systems 21 22 42 20 14 Manual sliding wall systems (MSW) ID 104377 Integrated all-glass systems (IGG) ID 104366 GEZE DOOR TECHNOLOGY AND GLASS SYSTEMS 07 10 Smoke and heat extraction systems Safety technology 16 08 07 Innovative system solutions POTENTIAL APPLICATIONS OF GEZE PRODUCTS Door technology The functionality, superior performance and reliability of GEZE door closers are impressive. A common design across the range, the ability to use them on all common door leaf widths and weights, and the fact that they can be individually adjusted makes their selection simple. They are continually being improved and enhanced with up-to-date features. For example, the requirements of fire protection and accessibility are fulfilled with a door closer system. Automatic door systems 15 GEZE automatic door systems open up a huge variety of options in door design. The latest, innovative highperformance drive technology, safety, ease of accessibility and first class universal drive design set them apart. GEZE offers complete solutions for individual requirements. 17 Smoke and heat extraction and window technology 21 GEZE smoke and heat extraction systems and ventilation technology provide complete systems solutions combining the many requirements of different types of windows. We supply a full range from energy efficient drive systems to natural ventilation and complete solutions for supplying and extracting air, also as certified SHEVs. 15 05 12 03 Safety technology GEZE safety technology sets the standards where preventative fire protection, access control and anti-theft security in emergency exits are concerned. For each of these objectives GEZE offers tailored solutions, which combine the individual safety requirements in one intelligent system and close doors and windows in case of danger in a coordinated manner. 21 18 Building systems 16 09 19 In GEZE’s Building Management System GEZE door, window and safety products can be integrated in to the security and control systems of the building. A central control and visualisation system monitors various automation components in the building and offers security through many different networking capabilities. Glass systems GEZE glass systems stand for open and transparent interior design. They can either blend discreetly into the architecture of the building or stand out as an accentuated feature. GEZE offers a wide variety of technologies for functional, reliable and aesthetic sliding wall or sliding door systems providing security with lots of design scope. Manual sliding door systems 43 G E Z E D O O R T E C H N O LO G Y A N D G L A S S S Y S T E M S GEZE GmbH P.O. Box 1363 71226 Leonberg Germany GEZE GmbH Reinhold-Vöster-Straße 21-29 71229 Leonberg Germany Telefon +49 7152 203

Emergency exit systems
Product brochure

Emergency exit systems Contents | GEZE EMERGENCY EXIT SYSTEMS Contents Overview … D OOR C ON TR O L U N I TS Connectable TZ 320 series … Connectable TZ 320 stainless steel series 14 T 320 terminal for bi-directional escape routes 20 LOC K IN G E LE M E N TS FTV 320 escape door lock 26 MA 500 holding magnet 30 SYSTE M S OLUT I O N S Emergency exit protection Nursery school solution– flexible and safe entrance and exit control for nursery schools Emergency exit protection Bi-directional emergency exit protection for doors with emergency exit function in both directions. Central control For doors in interlocking door systems 36 38 40 Hospital ward control visualised IN D IV ID UAL C O M P O N E N TS A N D ACCESSO RI ES Key switches 46 Emergency push buttons 49 Emergency exit signs 52 Power supply 53 Indicator lamps and signal horns 56 Synchronising unit 59 O P E R ATIN G E LE M E N TS myGEZE Control 62 myGEZE Visu 64 Accessories 65 … 4 GEZE EMERGENCY EXIT SYSTEMS | Overview APPLICATION TZ 320 Standard cTZ 320 Comfort with IO 420 extension module LOCAL OPERATION / DISPLAY Short-time release (20 s) Short-time release (1 s – infinite) ● ● Cancellation of short-time release with door closed ● ● Retriggering short-time release ● ● ● ● Pre-alarm (60 s) Pre-alarm (1 s – 10 min.) Alarm ● ● Permanent unlocking ● ● FTV 320 escape door lock 3x 3x Emergency exit electric strike type 331 / 332 3x 3x MA 500 holding magnet 2x 2x CONNECTION POSSIBILITIES Danger alarm system emergency unlocking ● ● Indirect activation ● ● Central emergency push button via safety circuit ● ● External key switch ● ● SCT 222 external key switch with … LEDs ●*** ● External emergency push button ● ● T 320 terminal (bi-directional escape route) ● ● Access control (short-time unlocking) ● ● Top lock (short-time unlocking) ● ● Timer (unlocking) external ● ● Timer (unlocking) internal ● ● Burglar alarm system (locking has priority) ● ● Programmable inputs … 7 Programmable outputs … 6 Flashlight / siren / alarm message ●* ● Motor lock ●* ● Lever lock ●* ● Swing door drive ●** ● Signal light controller ●** ● Additional electric strike ●* ● Output of different system states ●* ● Connection to BMS via myGEZE Control ● STANDARD Conform to EN 13637 ● ● Infrared interface for diagnosis, setting of parameters via ST 220 service terminal ● ● Alarm memory ● ● OTHER Integrated interlocking door system control ● ● Network function for fire alarm system, timer, burglar alarm system ● ● ● = yes I * Function can be realised via two freely configurable outputs. There are two outputs available on the TZ 320. If more outputs are required, the TZ 320 Comfort with IO 420 extension module must be used. | ** Two outputs are required for this function. | *** RP 220 relay board ID no. 102355 required. … 7 AC C ESS C ON T RO L A N D SA FE T Y Door control units Rescue routes must be individually adapted for each building – otherwise they are not safe. The door control unit plays an extremely important role in this respect: In normal circumstances, it lets authorised people pass through the door, and in an emergency, it opens for everyone. Use the wide selection of GEZE door control units with fire and danger alarm systems, escape door locks, motor locks and much more to bring your customised safety concept to life. … GEZE EMERGENCY EXIT SYSTEMS | Door control units TZ 320 Door control unit for controlling escape route doors with illuminated emergency exit sign, key switch and power supply ARE AS OF APP L I CAT I O N EN 13637-compliant protection of an emergency exit against unauthorised access Can be used on single and double leaf doors  Connectivity via bus enables e.g. interlocking door system control, forwarding of alarms, connection to building management system Can be combined with motor locks and swing door drives Realisation of a bi-directional emergency exit Flush-mounted installation ensures seamless integration into the building PR OD U CT F E AT U R ES  Flat impact cover enables fast and safe activation of the illuminated emergency push button in panic situations Coloured terminals simplify installation  Three freely configurable inputs and two freely configurable outputs offer numerous possibilities for additional components Number of inputs and outputs can be extended with the IO 420 extension module Illuminated emergency exit sign improves visibility Integrated power supply offers additional flexibility Integrated key switch enables authorised passing through the emergency exit Door control units | GEZE EMERGENCY EXIT SYSTEMS CON N ECTIV ITY P O SSI B LE FO R D O O R CO N TRO L UN I TS - TZ 320 SERI ES Connectivity – this is a top priority in this product series. You can realise complex applications here, because there are a large number of interfaces to other products and systems. These door control units can communicate with each other due to the integrated bus function. Messages can be visualised on a tableau or PC and can be forwarded to higher-ranking building management systems. Your escape route is secured against unauthorised access in any case. At the same time, the integrated emergency push button ensures access in emergency situations. TEC HN ICAL DATA TZ 320 BSN UP TZ 320 BSN AP Width 81 mm 77 mm Height 223 mm 197 mm Depth in flush-mounted sockets 62 mm deep 88 mm Acoustic signal 75 dB 75 dB Number of outputs … 2 Number of inputs … 3 Illuminated yes yes Operating voltage 24 V DC 24 V DC Contact current capacity 30 V / … A 30 V / … A With ribbon cable yes yes Type of installation Flush-mounted Surface-mounted Emergency push button yes yes Visual display yes yes Parameter setting ST 220 service terminal ST 220 service terminal Sabotage contact yes yes IP rating IP30 IP30 Current consumption 130 mA 130 mA Power supply for external devices (24 V DC) 600 mA 650 mA Service temperature -10 °C...+55 °C -10 °C...+55 °C Supply voltage 230 V 230 V Delayed emergency push button no no Cylinder type Euro profile half cylinder Euro profile half cylinder Conform to EN 13637 yes yes … 10 GEZE EMERGENCY EXIT SYSTEMS | Door control units TZ 320 STAN DA R D D O O R C O N T R O L U N I T – SYSTEM STR UCTUR E 230 V AC 50 HZ 230 V AC 50 Hz V GEZE BUS … 2 TS 5000 … MA 500 MST 210 Powerturn Slimdrive EMD GEZE BUS TK FTV 320 BMA EMA BMA … 5 EMA … 4 ZuKo ZuKo TZ 320 SN IQ lock C … 8 TZ 320 SN IQ lock EL … = flashlight I … = signal horn I … = alarm message I … = key switch I … = sensor strip I … = movement detector I … = contact sensor I … = main switch I BMA = fire alarm system I FTV 320 = escape door lock I FS = latch lock I EMA = burglar alarm system I MA 500 = holding magnet I MST 210 = motor lock control I Powerturn / Slimdrive EMD = swing door drive I TK = door contact I TS 5000 = door closer I ZuKo = access control FUNCTION AL D ES CR I P T I O N In the direction of escape, the door is held closed by an additional electrical locking element which is controlled by the door control unit as the central system unit. Authorised passing of the secured door can be by means of external activation devices such as key switches, access control or an intercom. In the direction of escape, authorised passage is also possible by means of the integrated key switch of the door control unit. If the door is to be passed through from the outside, the panic lock must be mechanically unlocked as well. Time monitoring of the door If the door is not closed after the release time for authorised activation has expired, a pre-alarm is triggered to draw attention to the time limit being exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch Passing of the door in case of an emergency In case of an emergency, the door can be released at any time via the integrated emergency push button. Visual and acoustic signal transmitters integrated in the door control unit signal unauthorised passing of the door. Central control and visualisation Due to the integrated bus function of the TZ 320, central visualisation and control of the individual doors can take place via myGEZE Control. Bus functions Burglar alarm systems (EMA), fire alarm systems (BMA) or timers (ZSU) can be connected to a door control unit in the bus system. The signals can be forwarded by the bus to all further door control units. Up to five groups are always possible. Note: forwarding the fire alarm system signal is not permitted with EN 13637 conforming control units. Other functions – Permanent unlocking – Locking – Acknowledging an alarm – Emergency unlocking via the fire alarm system Door control units | GEZE EMERGENCY EXIT SYSTEMS Design variants The variant with IQ lock C, a self-locking contact lock in place of the panic lock, offers increased ease of access from the outside by only one operating process. Mechanical unlocking of the lock and release of the emergency exit protection are carried out simultaneously. The lock is unlocked by the Euro profile cylinder via the integrated cylinder contact of the IQ lock C, and a short-time release is executed at the TZ 320 at the same time. The variant with IQ lock EL, a self-locking motor lock combined with swing door drive, offers increased access convenience due to the fully automatic opening of the door after authorised passage. In daytime operation the door control unit can be permanently unlocked so that passage via push button or radar sensor is possible by anyone. At night, the door control unit can be locked so that passage is only possible by authorised persons. In addition, the self-locking feature guarantees the doors are always locked in accordance with insurance requirements. Planning information The TZ 320 is very well equipped with two freely programmable outputs and three programmable inputs. If the requirements make more outputs or inputs necessary, the system TZ 320 Comfort with IO 420 extension module must be used. If, for example, alarm messages are required in addition to a swing door drive, or if other signals have to be forwarded to a central building management system, more than two outputs are necessary. System components – TZ 320 SN AP/UP door control unit – FTV 320 escape door lock – Emergency exit electric strike with latch lock or holding magnet with installation set and door contact Options – Flashlight, signal horn – SCT 220, SCT 222, SCT 320 external key switches – NOT 320 external emergency push button – Uninterrupted power supply (UPS) – T 320 terminal – ST 220 service terminal – IQ lock EL, EM, C, M – Slimdrive EMD, ECturn, Powerturn swing door drives – Extension of the digital inputs and outputs via IO 420 extension module – Connection to BACnet IP via myGEZE Control 11 12 GEZE EMERGENCY EXIT SYSTEMS | Door control units ORD E R IN FOR MAT I O N Designation Switch programme Version TZ 320 BSN door control unit, flush-mounted, EN 13637 Consisting of: a control unit with emergency push button, key switch with Euro profile half cylinder. Emergency exit sign, illuminated, power supply 24 V DC Jung AS 500 Jung LS 990 Gira E2 Gira E2 ID no. white stainless steel anthracite pure white matt 193509 193510 193511 193542 TZ 320 BSN door control unit, surface-mounted , EN 13637 Consisting of: a control unit with emergency push button, key switch with Euro profile half cylinder. Emergency exit sign, illuminated, power supply 24 V DC white aluminium green 193546 193545 TZ 320 BS door control unit, surface-mounted, EN 13637 Consisting of: control unit with emergency push button, key switch with Euro profile half cylinder, illuminated emergency exit sign, operating voltage 24 V DC white aluminium green 193544 193543 Door control unit configuration 199289 TZ 320 UP control unit Control unit with emergency push button impact cover made of transparent plastic 129586 Door control units | GEZE EMERGENCY EXIT SYSTEMS Products TZ 320 BSN door control unit, flush-mounted, EN 13637, Gira E2 pure white matt (193542) TZ 320 BSN door control unit, flush-mounted, EN 13637, Gira E2 anthracite (193511) TZ 320 BSN UP door control unit, EN 13637, Jung AS 500 white (193509) TZ 320 BSN door control unit, surface-mounted, EN 13637 (193545), TZ 320 BS door control unit, surface-mounted, EN 13637 (193543) TZ 320 BSN door control unit, surface-mounted, EN 13637 (193546), TZ 320 BS door control unit, surfacemounted, EN 13637 (193544) TZ 320 UP control unit (129586) TZ 320 BSN UP door control unit, EN 13637, Jung LS 990 stainless steel (193510) 13 14 GEZE EMERGENCY EXIT SYSTEMS | Door control units TZ 320 - stainless steel Door control unit for controlling escape route doors with illuminated emergency exit sign, key switch and power supply AR E AS OF APP L I CAT I O N EN 13637-compliant protection of an emergency exit against unauthorised access Can be used on single and double leaf doors Connectivity via bus enables e.g. interlocking door system control, forwarding of alarms, connection to building management system Can be combined with motor locks and swing door drives Realisation of a bidirectional emergency exit Flush-mounted installation ensures seamless integration into the building PR OD U CT F E AT U R ES  Flat impact cover enables fast and safe activation of the illuminated emergency push button in panic situations Coloured connectors facilitate electrical connection  Three freely configurable inputs and two freely configurable outputs offer numerous possibilities for additional components  Number of inputs and outputs can be expanded using the IO 420 extension module  Integrated power supply offers additional flexibility Integrated key switch enables authorised passing through the emergency exit  Robust and attractive stainless steel housing  Backlighting with LED backlight possible Installation in stainless steel box Door control units | GEZE EMERGENCY EXIT SYSTEMS CON N ECTIV ITY P O SSI B LE FO R D O O R CO N TRO L UN I TS - TZ 320 STAI N LESS STEEL SER I ES The design version of the TZ 320 is covered in high quality stainless steel. Because of this, it is particularly stable and offers increased protection against vandalism. The integrated sabotage protection is triggered once the front plate is removed. The identical designs of the surface-mounted and flush-mounted front plates make the two variants look almost identical. A distinction can only be established on the basis of the somewhat larger dimensions. This makes it possible to have a standardised look throughout a building. These door control units can be equipped with a “backlight” LED display. The LEDs can signal different functions, such as door closed (red) or door open (green), as well as LEDs continuous (green) or alarm (red). TEC HN ICAL DATA TZ 320 BSN stainless steel, flush-mounted socket set EN 13637 TZ 320 BSN stainless steel, flush-mounted socket set EN 13637 TZ 320 BSN stainless steel, surface-mounted set EN 13637 Width 98 mm 98 mm 78 mm Height 260 mm 260 mm 240 mm Depth 11,5 mm 70 mm 70 mm Acoustic signal 75 db 75 db 75 db Number of outputs … pcs. … pcs. … pcs. Number of inputs … pcs. … pcs. … pcs. Illuminated no no no Operating voltage 24 V DC 24 V DC 24 V DC Contact current capacity 30 V / … A 30 V / … A 30 V / … A With ribbon cable yes yes yes Type of installation flush-mounted flush-mounted surface-mounted Emergency push button yes yes yes Visual display yes yes yes Parameter setting ST 220 service terminal ST 220 service terminal ST 220 service terminal Sabotage contact yes yes yes IP rating IP30 IP30 IP30 Current consumption 130 mA 130 mA 130 mA Power supply for external devices (24 V DC) 950 mA 950 mA 950 mA Supply voltage 230 V 230 V 230 V Service temperature -10 - 55 °C -10 - 55 °C -10 - 55 °C Cylinder type Euro profile half cylinder Euro profile half cylinder Euro profile half cylinder Conform to EN 13637 yes yes yes POS ITION OF T H E D O O R C O N T R O L U N I T ACCO R DI N G TO EN … 3 637 90° … 1200 800 … 2 … 1 … 1 = emergency push button I … = direction of escape 600 15 16 GEZE EMERGENCY EXIT SYSTEMS | Door control units STAN DA R D D OOR C O N T R O L U N I T – SYST EM STRUCTURE 230 V AC 50 HZ 230 V AC 50 Hz V GEZE BUS … 2 TS 5000 … MA 500 MST 210 Powerturn Slimdrive EMD GEZE BUS TK FTV 320 BMA EMA BMA … 5 EMA … 4 ZuKo ZuKo TZ 320 SN IQ lock C … 8 TZ 320 SN IQ lock EL … = flashlight I … = signal horn I … = alarm message I … = key switch I … = sensor strip I … = movement detector I … = contact sensor I … = main switch I BMA = fire alarm system I FTV 320 = escape door lock I FS = latch lock I EMA = burglar alarm system I MA 500 = holding magnet I MST 210 = motor lock control I Powerturn / Slimdrive EMD = swing door drive I TK = door contact I TS 5000 = door closer I ZuKo = access control FU NCTION AL D ES CR I P T I O N In the direction of escape, the door is held closed by an additional electrical locking element which is controlled by the door control unit as the central system unit. Authorised passing of the secured door can be by means of external activation devices such as key switches, access control or an intercom. In the direction of escape, authorised passage is also possible by means of the integrated key switch of the door control unit. If someone wants to pass through the door from the outside, the panic lock must be mechanically unlocked as well. Time monitoring of the door If the door is not closed after the release time for authorised activation has expired, a pre-alarm is triggered to draw attention to the time limit being exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. Passing of the door in case of an emergency In case of an emergency, the door can be released at any time via the integrated emergency push button. Visual and acoustic signal transmitters integrated in the door control unit signal unauthorised passing of the door. Central control and visualisation Due to the integrated bus function of the TZ 320, central visualisation and control of the individual doors can take place via the TE 220 control panel or myGEZE Control. Bus functions Burglar alarm systems (EMA), fire detector systems (BMA) or timers (ZSU) can be connected to a door control unit in the bus system. The signals can be forwarded by the bus to all further door control units. Up to five groups are always possible. Note: Forwarding of the fire alarm system signal is not permitted for EN 13637 conforming control units. Other functions – Permanent unlocking – Locking – Acknowledging an alarm – Emergency unlocking via the fire alarm system Door control units | GEZE EMERGENCY EXIT SYSTEMS Design variants The variant with IQ lock C, a self-locking contact lock in place of the panic lock, offers increased ease of access from the outside by only one operating process. Mechanical unlocking of the lock and release of the emergency exit protection are carried out simultaneously. The lock is unlocked by the Euro profile cylinder via the integrated cylinder contact of the IQ lock C, and a short-term release is executed at the TZ 320 at the same time. The variant with IQ lock EL, the self-locking motor lock combined with swing door drive, offers increased ease of access due to the fully automatic opening of the door after authorised passage. In daytime operation the door control unit can be permanently unlocked so that passage via push button or radar sensor is possible by anyone. At night, the door control unit can be locked so that passage is only possible by authorised persons. In addition, the self-locking feature guarantees the doors are always locked in accordance with insurance requirements. Planning information The TZ 320 is very well equipped with two freely programmable outputs and three programmable inputs. If the requirements make more outputs or inputs necessary, the system TZ 320 Comfort or the the IO 420 extension module must be used. If, for example, alarm signals are needed in addition to a swing door drive, or if other signals have to be forwarded to a central building management system, more than two outputs are necessary. System components – TZ 320 SN AP/UP door control unit – FTV 320 escape door lock – Emergency exit electric strike with latch lock or holding magnet with installation set and door contact Options – Flashlight, signal horn – External key switch SCT 220, SCT 222, SCT 320 – NOT 320 external emergency push button – Uninterrupted power supply (UPS) – T 320 eerminal – ST 220 service terminal – IQ lock EL, EM, C, M – Slimdrive EMD, ECturn, Powerturn swing door drives – TE 220 control panel – Connection to BACnet IP via my GEZE Control 17 18 GEZE EMERGENCY EXIT SYSTEMS | Door control units O RDE R IN FOR MAT I O N Designation Version ID no. stainless steel TZ 320 BSN door control unit stainless steel, surface-mounted set, EN 13637 Consisting of: stainless steel front plate surface-mounted, standard, with recess for Euro profile cylinder, stainless steel housing surface-mounted, TZ 320 control unit flush-mounted with emergency, push button SCT 320 key switch, emergency exit sign pre-mounted, SCT design adhesive frame, 24 V DC power supply, output current max. 950 mA, 230 V AC power supply, operating voltage 24 V DC 193506 stainless steel TZ 320 BSN door control unit stainless steel, flush-mounted set, EN 13637 Consisting of: stainless steel front plate flush-mounted, standard, with recess for Euro profile cylinder, stainless steel housing flush-mounted, TZ 320 UP control unit with emergency, push button SCT 320 key switch, emergency exit sign pre-mounted, SCT design adhesive frame, 24 V DC power supply, output current max. 950 mA 230 V AC power supply, 24 V DC operating voltage 193507 TZ 320 BSN stainless steel door control unit, flush-mounted socket set, EN 13637 Consisting of: stainless steel front plate, flush-mounted standard with recess for Euro profile cylinder, white spacer frame, TZ 320 UP control unit with emergency push button, SCT 320 key switch, emergency exit sign pre-mounted, SCT design adhesive frame, 24 V DC power supply Not included: wall fixing screws Output current max. 950 mA, power supply 230 V AC Operating voltage 24 V DC stainless steel 193508 TZ 32x stainless steel housing surface-mounted flush-mounted 155016 155017 Stainless steel front plate, standard EN 13637 Incl. Makrolon panel with pre-mounted emergency exit sign surface-mounted flush-mounted 193550 193552 Stainless steel front plate RFID, EN 13637 With recess for RFID reader, incl. Makrolon panel with pre-mounted emergency exit sign surface-mounted flush-mounted 193551 193553 Door control unit configuration 199289 TZ 320 UP control unit Control unit with emergency push button impact cover made of transparent plastic 129586 ACCES SORIES Spacer frame for stainless steel housing surface-mounted For installation of the door control unit with surface-mounted stainless steel housing 158696 Spacer frame for stainless steel housing surface-mounted For installation of the door control unit with flush-mounted stainless steel front plate in standard flush-mounted sockets 155030 LED-Backlight, GN/RD For optical backlighting of the stainless steel front plate 155031 SCT design adhesive frame, rectangular/round For attachment around the Euro profile cylinder recess on the front plate. 155034 Accessories mains connection Strain relief of the cables, earthing of the V2A housing Connection of the power supply circuit through Wago connector 155035 Door control units | GEZE EMERGENCY EXIT SYSTEMS Products TZ 320 BSN door control unit stainless steel, surface-mounted set, EN 13637(193506) TZ 320 BSN door control unit stainless steel, flush-mounted set, EN 13637 (193507) TZ 320 BSN door control unit stainless steel, flush-mounted socket set, EN 13637 (ID 193508) TZ 32x stainless steel housing surface-mounted (155016) TZ 32x stainless steel housing flush-mounted (155017) Stainless steel front plate, standard, EN 13637 (193550) Stainless steel front plate RFID, surface-mounted EN 13637 (193551) TZ 320 UP control unit (129586) 19 20 GEZE EMERGENCY EXIT SYSTEMS | Terminal T 320 terminal Slave control unit for bi-directional escape routes with a TZ 320 or TZ 322 with integrated key switch ARE AS OF APP L I CAT I O N   Terminal functions as additional interface for a TZ 320 to trigger an indirect release of a bi-directional emergency exit Realisation of a bi-directional emergency exit Realisation of an escape balcony PR OD U CT F E AT U R ES  Flat impact cover enables fast and safe activation of the illuminated emergency push button in panic situations Coloured connectors facilitate electrical connection Integrated key switch enables authorised passing through emergency exit Illuminated emergency exit sign improves visibility Terminal | GEZE EMERGENCY EXIT SYSTEMS TE R MIN AL FOR B I - D I R ECT I O N A L ESCA P E RO UTES - T 320 SER I ES Your escape route goes in both directions? No problem! Doors that are to secure the escape route in both directions are equipped with a TZ 320 on one side and a T 320 on the other. Thus, in case of danger, the door can be safely unlocked from both sides at any time via an emergency push button. The activation of the electric locking element can be controlled via the terminal as well as via the door control unit. This locking element keeps the doors locked and prevents unauthorised access. TEC HN ICAL DATA T 320 AP terminal T 320 UP control unit Acoustic signal 75 dB 75 dB Illuminated optional no Operating voltage 24 V DC 24 V DC Width 77 mm for installation in 55 mm grid Height 197 mm for installation in 55 mm grid Depth 88 mm in flush-mounted sockets 62 mm deep With ribbon cable yes yes Type of installation Surface-mounted Flush-mounted Emergency push button yes yes Visual display yes yes Sabotage contact yes yes IP rating IP30 IP30 Current consumption 100 mA 100 mA Temperature range -10 °C...+55 °C -10 °C...+55 °C Supply voltage 24 V DC 24 V DC Delayed emergency push button no no Supply voltage 230 V 230 V Delayed emergency push button no no Cylinder type Euro profile half cylinder - Conform to EN 13637 yes yes BI-D IR ECTION A L ESCA P E R O U T E – SYSTEM STRUCTURE GEZE BUS … 2 TS 5000 BMA … FTV 320 … ZuKo … TZ 320 SN T 320 … 230 V AC 50 HZ … = signal horn I … = alarm message I … = Toplock I … = key switch I … = panic lock I … = terminal / door control unit 21 22 GEZE EMERGENCY EXIT SYSTEMS | Terminal SYSTE M D ES C R IP T I O N Authorised passage in the 1st direction of escape Authorised passage through the secured door in the 1st direction of escape is by means of a key switch integrated in the door control unit. In addition, passage via external elements e.g. access control or a key switch is also possible. The door is released for authorised passage for a configurable amount of time (short-time release). Authorised passage in the 2nd direction of escape Authorised passage through the secured door in the 2nd direction of escape is by means of a key switch integrated in the terminal. In addition, passage via external elements e.g. access control or a key switch is also possible. The door is released for authorised passage for a configurable amount of time (short-time release). Time monitoring of the door If the door is not closed after the release time for authorised activation has expired, a pre-alarm is triggered to draw attention to the time limit being exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. The door is equipped with a door closer to ensure it closes automatically after passage. Passing the door in case of an emergency The door can be released at any time in case of an emergency via the emergency push button integrated on the door control unit and/or on the terminal. Visual and acoustic signal transmitters integrated in the door control unit and in the terminal signal unauthorised passing of the door. There is also the possibility of triggering external signal transmitters via an alarm contact or relaying a message to a building management system. O RDE R IN FOR MAT I O N Designation Version ID no. T 320 AP terminal, EN 13637 Consisting of: control unit with emergency push button, key switch with Euro profile half cylinder, non-illuminated emergency exit sign white aluminium green 193548 193547 T 320 UP control unit (No complete flush-mounted set available, assembled of individual components) 140999 Terminal | GEZE EMERGENCY EXIT SYSTEMS Products T 320 AP control unit (193547) T 320 AP control unit (193548) T 320 UP control unit (140999) 23 24 25 AC C ESS C O N T RO L A N D SA FE T Y Locking elements A hazardous situation can cause panic and represent a danger to life – which is why it’s even more important that electrically locked doors clear the escape route immediately. Locking elements such as the GEZE escape door locks, react immediately when they are released by authorised parties or someone presses the emergency push button. Other advantages: they save space, are easy to install and provide protection against manipulation and vandalism, due to clever devices. We are happy to help you choose the right locking elements for your emergency exit. 26 GEZE EMERGENCY EXIT SYSTEMS | Locking element FTV 320 Escape door lock for doors in rescue routes ARE AS OF APP L I CAT I O N Single and double leaf doors Installation in the frame or the door leaf ensures a tidy appearance Can be used for numerous other safety solutions that require a fail-safe principle PR OD U CT FE AT U R ES  Unique cross latch mechanism guarantees secure locking  Integrated feedback contact ensures reliable monitoring of the door  Integrated sabotage monitoring secures the locking mechanism against manipulation  Variety of face plates and accessories offers a solution for almost every door situation Locking element | GEZE EMERGENCY EXIT SYSTEMS TEC HN ICAL DATA FTV 320 Height … mm Width 15 mm Depth 38 mm Operating voltage 24 V DC Current consumption in locked state 100 mA Service temperature -20 °C...+60 °C Latch preload 3,000 N Break-open resistance 5,000 N Clearance … +/- … mm DIN direction universal Feedback contact yes Fail-safe yes Conform to EN 13637 yes PR OD U CT S CA LE D R AW I N G S … 40 … 2 20 25 … 186 200 186 186 93 200 R1 … 200 … 24 2) .5(x n5 11 14 … = ID 158906 FTV 320 escape door lock face plate 20 x 200 x … mm, round for solid leaf doors (wood) I … = ID 158908 FTV 320 escape door lock Face plate 24 x 200 x … mm, rectangular, for tubular-framed door I … = ID 158913 FTV 320 escape door lock face plate 25 x 200 x … mm, rectangular, alternative version FTÖ 331 27 28 GEZE EMERGENCY EXIT SYSTEMS | Locking element PRO D U CT F E ATU R ES Planning reliability and simple consulting One escape door lock for many applications. The types of installation DIN right / DIN left, horizontal / vertical, in door leaf or door frame make the FTV 320 extremely versatile. Exchange with products from other manufacturers is no problem. The comprehensive range of accessories complies with the standard dimensions. Time-saving and failsafe Additional components such as relay boards are not necessary. The double assignment of terminals is not required, nor is the setting of cable bridges between two terminals. Space-saving The small dimensions and omission of the latch lock previously required, use of the FTV 320 avoids unnecessary recesses in the door or frame. Leaving more room for fireproof insulation on fire protection doors. Cables can be routed past the housing of the escape door lock. Simple to install Locking device and face plate are delivered pre-mounted. Two fixing screws are all that is required for safe attachment. The strike plate on the opposite side is also installed using only two screws. There is no need for a latch lock to be installed. Protection against vandalism and manipulation Unlike conventional latch locks, the cross latches of the FTV 320 are blocked in the locked state, which prevents them from being manipulated using a cheque card. The mechanism and integrated control circuit board are protected against manipulation attempts and report any attempts to a higher-order level. FT V 320 ES CA PE D O O R LO CK – O R D E R I N FO R M ATI O N Designation DIN door stop FTV 320 escape door lock Face plate 20 x 200 x … mm, round for solid leaf doors (wood) left/right Version 158906 ID no. FTV 320 escape door lock Face plate 24 x 200 x … mm, round for solid leaf doors (steel) left/right 158909 FTV 320 escape door lock Face plate 22 x 220 x … mm, rectangular for tubular-framed doors left/right 158907 FTV 320 escape door lock Face plate 24 x 200 x … mm, rectangular for tubular-framed doors left/right 158908 FTV 320 escape door lock Face plate 28 x 200 x … mm, rectangular for tubular-framed doors left/right 158910 FTV 320 escape door lock Face plate 30 x 200 x … mm, rectangular for tubular-framed doors left/right 158911 FTV 320 escape door lock Angled face plate 30 x 48 x 220 x … mm, rectangular Alternative version FTÖ 331 left/right 158912 FTV 320 escape door lock Face plate 25 x 200 x … mm, rectangular Alternative version FTÖ 331 left/right 158913 FTV 320 escape door lock Face plate with lock latch guide 35 x 200 x … mm, rectangular Alternative version FTÖ 331 left/right 158914 Locking element | GEZE EMERGENCY EXIT SYSTEMS FT V 320 ES CA P E D O O R LO C K – O R D E R I N FO RM ATI O N Designation DIN door stop Version ID no. Strike plate 20 x 110 x 3, round for solid leaf doors (wood) left/right stainless steel 159059 Strike plate 20 x 140 x 3, round for solid leaf doors (wood) left/right stainless steel 159050 Lipped strike plate, can be shortened 20 x 140 x … mm (core dimensions), round for solid leaf doors (wood) left/right stainless steel 159056 Adjustable lipped strike plate, can be shortened 20 x 140 x … mm (core dimensions), round for solid leaf doors left/right stainless steel 159063 Strike plate 24 x 110 x … mm, round for solid leaf doors left/right stainless steel 159061 Strike plate 24 x 140 x … mm, round for solid leaf doors (steel) left/right stainless steel 159053 Lipped strike plate, can be shortened 24 x 140 x … mm (core dimensions), round for solid leaf doors (steel) left/right stainless steel 159058 Adjustable lipped strike plate, can be shortened 24 x 140 x … mm (core dimensions), round for solid leaf doors left/right stainless steel 159064 Strike plate 20 x 110 x 3, rectangular for tubular-framed doors left/right stainless steel 163768 Strike plate 22 x 220 x … mm, rectangular for tubular-framed doors left/right stainless steel 159051 Strike plate 24 x 110 x 3, rectangular for tubular-framed doors left/right stainless steel 163769 Strike plate 24 x 130 x … mm, rectangular for tubular-framed doors left/right stainless steel 159060 Strike plate 24 x 140 x … mm (core dimensions), rectangular for tubular-framed doors left/right stainless steel 159052 Lipped strike plate, can be shortened 24 x 140 x … mm (core dimensions), rectangular for tubular-framed doors left/right stainless steel 159057 Adjustable lipped strike plate, can be shortened 24 x 140 x … mm (core dimensions), rectangular for tubular-framed doors left/right stainless steel 159065 Strike plate 28 x 130 x … mm, rectangular for tubular-framed doors left/right stainless steel 159062 Strike plate 28 x 140 x … mm, rectangular for tubular-framed doors left/right stainless steel 159054 Strike plate 30 x 140 x … mm, rectangular for tubular-framed doors left/right stainless steel 159055 Strike plate support 20 x 140 x … mm, rectangular left/right stainless steel 159066 Strike plate support 24 x 140 x … mm, rectangular left/right stainless steel 159067 Strike plate support 24 x 140 x … mm, rectangular left/right stainless steel 159068 Support FTV 320 24 x 200 x … mm, rectangular left/right stainless steel 159072 Support FTV 320 24 x 200 x … mm, rectangular left/right stainless steel 159071 Strike plate support 28 x 140 x … mm, rectangular left/right stainless steel 159069 Strike plate support 28 x 140 x … mm, rectangular left/right stainless steel 159070 29 30 GEZE EMERGENCY EXIT SYSTEMS | Locking element MA 500 holding magnet For magnetic locking of emergency exits in accordance with the fail-safe principle ARE AS OF APP L I CAT I O N Doors along escape and rescue routes Emergency exits PR OD U CT FE AT U R ES  Integrated monitoring controls the locking status  Separate door contact enables door status message  Different installation sets offer three different installation situations Locking element | GEZE EMERGENCY EXIT SYSTEMS TEC HN ICAL DATA MA 500 Width 265 mm Height 66 mm Depth 41 mm Type of installation with corresponding installation set (hinge side, opposite hinge side or reveal) Service temperature -10 – 50 °C IP rating IP30 Operating voltage 24 V DC Current consumption 250 mA Feedback contact yes Fail-safe yes Conform to EN 13637 yes PR OD U CT S CA LE D R AW I N G IN STA LLATION SE T M A … 0 0, H I N G E SI D E 75 75 95 … 115 … 6 24 115 95 M6x20 … 33 … 33 mm … 2 115 16 26 26 17 33 146 24 23 … 8 37 24 26 … RWS M6x20 … 9 10 115 270 330 … = drilling template hinge side I … = door edge lock side I … = door DIN right I … = door DIN left I … = magnet with counterplate I … = mounting plate I … = lock washer I … = adjusting path I … = installation bracket I 10 = mounting bracket 31 GEZE EMERGENCY EXIT SYSTEMS | Locking element INSTA LLATION S E T M A … 0 0, O P P O SI T E H I NG E SI DE 10 16 115 115 20 RWS 17 26 … 154 … 2 … 24 … 17 26 … M6x20 26 71 … 146 57 33 33 M6x20 … 26 … 33 mm 20 … 20 270 75 20 20 30 … 7 … = drilling template opposite hinge side I … = frame lock side I … = door DIN right I … = door DIN left I … = magnet with counterplate I … = retaining plate I … = lock washer I … = adjusting path I … = installation bracket I 10 = mounting bracket INSTA LLATION S E T M A … 0 0, M O U N T I N G W I THI N R EVEAL 270 … 33 … 3 … 6 72 … 7 155 … 20 20 … 4 … 26 … 30 29 20 20 … 10 26 … 3 26 M6x20 11 29 33 29 26 17 RWS M6x20 … 20 115 26 115 75 32 … 6 30 20 20 155 20 20 … = drilling template mounting within reveal I … = reveal lock side I … = door DIN right I … = door DIN left I … = magnet with counterplate I … = retaining plate on the door I … = retaining plate I … = lock washer I … = lintel I 10 = mounting bracket I 11 = mounting bracket on the reveal Locking element | GEZE EMERGENCY EXIT SYSTEMS O R D E R IN FORM AT I O N Designation Version ID no. MA 500 holding magnet With counterplate silver-coloured 024740 Installation set MA 500, hinge side silver-coloured 024731 Installation set MA 500, opposite hinge side silver-coloured 024732 Installation set MA 500, mounting within reveal silver-coloured 025727 Surface-mounted magnetic contact Sensing distance 21 mm white 200386 Reed contact set white 106133 33 34 35 AC C ESS C O N T RO L A N D SA FE T Y System solutions We offer you complete solutions. From the initial consultation, the products and their installation through to the service following commissioning. Everything is tailored to your specific demands and needs. Our industry experts fully understand your concerns and will put together an individually tailored solution package. 36 GEZE EMERGENCY EXIT SYSTEMS | System solutions Emergency exit protection NURSE RY S C HOO L S O LU T I O N – F LE X I B LE AN D SAFE EN TRAN CE AN D EX I T CO N TR O L FO R N U R S E RY S CH O O LS With this emergency exit protection system for doors in nursery schools, the emergency exit is always locked and thus reliably protected against unauthorised passage. Unauthorised use of the emergency exit door by children can thus best be prevented by an approved system. The special feature of this system is the push button on the inside, which is positioned at a height of … m, inaccessible for children. In addition, the outside push button can be enabled or disabled via a switch for the parents during the arrival and pick-up periods. The activation of the emergency push-button – at a level children can reach – immediately releases the door and is signalled by both visual and acoustic alarms. This solution is also suitable for existing doors which are already fitted with an electric strike and a knob or pull handle on the outside. … 3 … 5 … 7 … 8 … 1 = panic lock with transmission function “E” on site I … = TS 4000/TS 5000 door closer I … = push button at … m height I … = switch to activate or deactivate the exterior push button I … = TZ 320 SN door control unit, surface-mounted/flush-mounted I … = FTV 320 escape door lock I … = A5000--B electric strike I … = key switch I … = push button outside System solutions | GEZE EMERGENCY EXIT SYSTEMS SYSTEM COMPONENTS TZ 320 SN door control unit, surface-mounted/flush-mounted ● FTV 320 escape door lock ● A5000--B electric strike ● RP 220 relay board ● Push button at … m height ● Push button outside ● Switch to enable or disable the outside push button ● TS 4000/TS 5000 door closer ● Panic lock with transmission function "E" on site ● OPTIONAL COMPONENTS Swing door drive as an alternative to the door closer for automatic door operation Holding magnet with installation set and door contact instead of escape door lock Flashlight Signal horn Uninterruptible power supply (UPS) Timer instead of the switch ● = yes SYSTE M D ES CR I P T I O N Passage by nursery school personnel Personnel triggers a short-time release on the door control unit by activating the outside key switch. The door can then be passed using the key on the panic lock. Pick up and drop off times The outside push button can be enabled or disabled via a switch in the office or on the door. This means that parents can trigger a short-time release when they are bringing or collecting their children, and open the door from the outside. Parents can leave the nursery school again by opening the door using the push button mounted at a height of … m. The installation height of … m means the push button is out of children's reach. Time monitoring of the door If the door is not closed after the release time has expired, a pre-alarm is triggered. This is to draw attention to the fact that the time has been exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. The door is equipped with a door closer to ensure it closes automatically after passage. Passing of the door in case of an emergency The door can be released at any time in an emergency by pressing the integrated emergency push button on the door control unit which is usually installed at a height of 850 mm and is thus also accessible for children. Visual and acoustic signal transmitters integrated in the door control unit signal passing of the door. There is also the possibility of triggering external signal transmitters via an alarm contact or relaying a message to a building management system. Burglary protection To lock the door in accordance with insurance requirements, nursery school staff must lock it manually using the panic lock. 37 38 GEZE EMERGENCY EXIT SYSTEMS | System solutions Emergency exit protection BI- D IR ECTION A L E M E R G E N CY E X I T P R OT ECTI O N FO R DO O R S W I TH EM ER G EN CY EX I T FUN CT ION IN BOTH D IR ECTIO N S. In the case of doors that serve as an escape route in both directions, a special system solution is necessary in order for them to make passage possible in both directions in emergency situations. With the GEZE system solution, doors along escape routes are generally held closed via an additional electrical locking element and thus reliably secured against unauthorised passage. Passage of the emergency exits is controlled by the TZ 320 door control unit. The T 320 terminal is fitted in the second direction of escape. In case of danger, the door can be safely unlocked from both sides at any time via an emergency push button. The door can be controlled and monitored via the T 320 terminal and via the TZ 320 door control unit. … 3 … 4 … = TS 4000/TS 5000 door closer I … = TZ 320 SN door control unit, surface-/flush-mounted I … = FTV 320 escape door lock I … = T 320 terminal surface- or flush-mounted System solutions | GEZE EMERGENCY EXIT SYSTEMS SYSTEM COMPONENTS TZ 320 SN door control unit, surface-mounted/flush-mounted ● T 320 terminal surface- or flush-mounted ● FTV 320 escape door lock ● TS 4000/TS 5000 door closer ● OPTIONAL COMPONENTS Holding magnet with installation set and door contact instead of escape door lock Flashlight Signal horn Uninterruptible power supply (UPS) Access control Connection to BACnet IP via myGEZE Control ● = yes SYSTE M D ES CR I P T I O N Authorised passage in the 1st direction of escape Authorised passage through the secured door in the 1st direction of escape is by means of a key switch integrated in the door control unit. In addition, passage via external elements e.g. access control or a key switch is also possible. The door is released for authorised passage for a configurable amount of time (short-time release). Authorised passage in the 2nd direction of escape Authorised passage through the secured door in the 2nd direction of escape is by means of a key switch integrated in the terminal. In addition, passage via external elements e.g. access control or a key switch is also possible. The door is released for authorised passage for a configurable amount of time (short-time release). Time monitoring of the door If the door is not closed after the release time has expired, a pre-alarm is triggered. This is to draw attention to the fact that the time has been exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. The door is equipped with a door closer to ensure it closes automatically after passage. Passing the door in case of an emergency The door can be released at any time in case of an emergency via the emergency push button integrated on the door control unit and/or on the terminal. Visual and acoustic signal transmitters integrated in the door control unit and in the terminal signal unauthorised passing of the door. There is also the possibility of triggering external signal transmitters via an alarm contact or relaying a message to a building management system. 39 40 GEZE EMERGENCY EXIT SYSTEMS | System solutions Central control FOR D OOR S IN IN T E R LO CK I N G D O O R SYSTEM S This system allows interlocking door systems (active or passive) in the course of escape routes, e.g. in operating wings, laboratory and quarantine wards, to be achieved. This is the case when several doors are released in succession and may only be passed once the respective previous door has been closed again. The doors in one group mutually lock each other. A door control unit can be assigned to several groups at the same time. The interlocking door system relations can be changed at any time through simple parameter setting. A maximum of 10 interlocking door groups with altogether up to 63 door control units each are possible per bus system. For both types of interlocking door system, immediate access can be gained by activating the emergency push button. The interlocking door system function can be switched on and off by means of key switches. … 3 … 2 … 2 … = TS 4000 / TS 5000 door closer I … = TZ 320 SN door control unit, surface-/flush-mounted, reader integrated I … = traffic light display red / green I … = FTV 320 escape door lock System solutions | GEZE EMERGENCY EXIT SYSTEMS SYSTEM COMPONENTS TZ 320 door control unit ● FTV 320 escape door lock ● Traffic light display red/green ● Push button ● Power supply ● TS 4000 / TS 5000 door closer ● OPTIONAL COMPONENTS Holding magnet with installation set and door contact instead of escape door lock Red indicator lamp instead of the traffic light display IQ lock EL motor lock IQ lock EM lever lock IQ lock C contact lock Slimdrive EMD / Powerturn swing door drive Timer (ZSU) Flashlight Signal horn Uninterruptible power supply (UPS) ● = yes SYSTE M D ES CR I P T I O N Active interlocking door system In the closed state, all the doors configured as part of an active interlocking door group are locked. If one of these doors is released short-term via respective activation devices, it transmits a signal to all the other doors in the group at the same time and prevents short-time unlocking. Passive interlocking door system In contrast to the active interlocking door system, all the doors configured as part of a passive interlocking door system are not generally locked when in a closed state. If one of these doors is opened, it transmits a signal to all other doors and locks these. Mixed interlocking door system (active and passive) Both interlocking door system types can be combined in one interlocking door group. Continued locking of interlocking door system doors for pressure compensation or air purification, e.g. in clean rooms A time can be set for the interlocking door system to remain locked after it has been passed through (locking all the doors of an interlocking door group). Different times can be set at all the door control units of an interlocking door system. It is possible, for example, to keep the door locked for … s following passage from a clean room to a grey room, and for 15 s following passage in the opposite direction (grey room > clean room), since more time is required to clean the air in this case. Authorised passage from the non-secured area into the interlocking door system Authorised passage from the non-secured area is by means of electric access control using a card reader or the integrated key switch of the door control unit. The door is released for authorised passage for a configurable amount of time (shorttime release). 41 42 GEZE EMERGENCY EXIT SYSTEMS | System solutions SYSTE M D ES C R IP T I O N – C O N T I N UAT I O N Authorised passage out of the interlocking door system In the interlocking door system, the doors are released via a push button without special authorisation. If a higher safety standard is required, an electric access control or mechanical key switch must be used here as well. Authorised passage out of the secured area into the interlocking door system In the secured area, the door is released via a push button without special authorisation. If a higher safety standard is required, an electric access control or mechanical key switch must be used here as well. Opening multiple doors in an interlocking door system for transportation purposes The "permanent unlocking" function on the door control units is used to disable the interlocking door system function. Several doors in one interlocking door group can then be opened at the same time. If deactivation of the interlocking door system is not possible for safety reasons, the "permanent unlocking" function can be suppressed on the door control units. Visual display of the interlocking door system status A locked interlocking door system is indicated by the integrated LEDs on the door control unit flashing red. In addition, the traffic light display is green when the interlocking door system can be entered and red when it is locked. As an option, the system can display only a red signal; this indicates that the interlocking door system is occupied. If no visual signal is displayed, the door can be passed. Time monitoring of the door If the door is not closed after the release time has expired, a pre-alarm is triggered. This is to draw attention to the fact that the time has been exceeded. If the pre-alarm time is also exceeded, a door alarm is triggered and has to be acknowledged by the key switch. The door is equipped with a door closer to ensure it closes automatically after passage. Automated interlocking door systems In the context of interlocking door system control it is also possible to activate swing door drives via the door control unit and thus to open and close doors in defined building sections. If a door is locked by the door control unit (basic state of active interlocking door system), the door drive is in the so-called night mode. If the short-time release is triggered, the drive is automatically activated and the door opens. After the hold-open time set on the drive has passed, the door closes and the door control unit locks the door. If a door is in an unlocked state (basic state of passive interlocking door system), the door drive is switched to automatic mode. The activation devices connected to the drive are active as long as the door is unlocked. If the door control unit locks, all the activation devices belonging to the automation are without function. Passing of the door in case of an emergency The door can be released in case of an emergency at any time via the integrated emergency push button. Visual and acoustic signal transmitters integrated in the door control unit signal unauthorised passing of the door. There is also the possibility of triggering external signal transmitters via an alarm contact or relaying a message to a building management system. Integrating doors without escape route function Other types of doors such as sliding doors, industrial doors etc. can be integrated in a simple interlocking door system relation by means of the door control units. In this case, the door control unit serves only as an interlocking door system control which interrupts or releases the activation devices of the other doors. Its standardisation means that this solution is more straightforward than an interlocking door system control via a programmable logic controller (PLC) which generally requires separate programming and a cable plan and wiring diagram. System solutions | GEZE EMERGENCY EXIT SYSTEMS 43 44 45 AC C ESS C ON T RO L A N D SA FE T Y Individual components and accessories 46 GEZE EMERGENCY EXIT SYSTEMS | Individual components Key switches SCT 320 U P K E Y SW I TC H Areas of application – Authorised control of operating statuses on various GEZE products – Approved for use with GEZE emergency exit system door control units – Designed for Euro profile half cylinder 30/10 – Dry internal applications – Flush-mounted installation makes almost flush integration possible with a low installation height Product features – Two-sided switching operation, with Euro profile half cylinder and three keys – With ribbon cable for convenient connection to the emergency exit system flush-mounted door control unit – With integrated sabotage contact – Designed for installation in 55-type flush-mounted ranges TECHN ICAL DATA SCT 320 UP IP rating IP20 Type of installation Flush-mounted Material Plastic Switching voltage 24 V DC Switching current 1A SCT … 20 U P K E Y SW I TC H Areas of application – Authorised control of operating statuses on various GEZE products – Approved for use with GEZE emergency exit system door control units – Designed for Euro profile half cylinder 30/10 – Dry internal applications – Flush-mounted installation makes almost flush integration possible with a low installation height Product features – With single frame – Two-sided switching operation, with Euro profile half cylinder and three keys TECHN ICAL DATA SCT 220 UP IP rating IP20 Type of installation Flush-mounted Material Stainless steel or plastic Switching current 10 A Switching voltage 250 V AC Individual components | GEZE EMERGENCY EXIT SYSTEMS SCT … 2 … K E Y S W I TCH W I T H LE D Areas of application – Authorised control of operating statuses on various GEZE products – Approved for use with GEZE emergency exit system door control units – Designed for Euro profile half cylinder 30/10 – Outer areas due to high IP rating Product features – With integrated LED display for status feedback – Right LED red/green and left LED yellow – High-quality aluminium front plate – Two-sided switching operation, with Euro profile half cylinder and three keys – Sabotage-proof design, can only be opened with key TEC HN ICAL DATA SCT 222 with LED IP rating IP54 Type of installation Surface or flush-mounted Material Aluminium Switching current 5A Switching voltage 230 V AC KE Y S WITC H STAY- P U T W I T H O U T E U R O PR O FI LE HALF CYLI N DER Areas of application – For authorised activation of automatic doors – For authorised changing of the mode of operation on automatic doors – Internal application, some outer areas Product features – IP rating IP54 – Stay-put on both sides – Cover can only be removed with the key – Light alloy housing TEC HN ICAL DATA SCT stainless steel IP rating IP54 Type of installation Flush-mounted installation Material Light alloy housing Switching current 5A Switching voltage 230 V AC 47 48 GEZE EMERGENCY EXIT SYSTEMS | Individual components EURO -P R OF ILE H A LF CY L I N D E R … 0 M M … 0 /1 … Areas of application – Lock cylinder for activation of one or both sides of the door – For key switches, manual locking devices, hook bolt locks Product features – Euro profile half cylinder 30/10 ORD E R IN FOR MAT I O N Designation Type of installation Version ID no. Flush-mounted SCT 320 key switch Two-sided switching operation, with Euro profile half cylinder and three keys Flush-mounted Flush-mounted Frame available separately. alpine white pure white matt anthracite 131984 130370 132278 SCT 221 key switch Single-sided switching operation, without Euro profile half cylinder silver-coloured silver-coloured 054240 054532 SCT 220 key switch, Jung LS 990 Flush-mounted Two-sided switching operation, with Euro profile half cylinder and three keys stainless steel 094170 SCT 220 key switch, GIRA E2 Flush-mounted Two-sided switching operation, with Euro profile half cylinder and three keys pure white matt 094012 SCT 222 key switch with LEDs Surface-mounted Two-sided switching operation, with Euro profile half cylinder and three keys Flush-mounted silver-coloured silver-coloured 100065 100064 Key switch stay-put without Euro profile half cylinder silver-coloured 111357 Euro-profile half cylinder 40 mm 30/10 Flush-mounted Surface-mounted Flush-mounted 090176 Individual components | GEZE EMERGENCY EXIT SYSTEMS Emergency push buttons NOT 320 E ME R G E N CY P U S H B U T TO N Areas of application – Mains voltage can be switched off in the case of an emergency and during maintenance work – Indirect activation of GEZE emergency exit system door control units – Opening of automatic doors in case of an emergency Product features – LED lighting for better visibility, even in the dark – Re-usable cover that protects against dust and dirt – Contact system consists of one normally closed contact and one normally opened contact – Flat impact cover enables fast and safe activation of the illuminated emergency push button in panic situations TEC HN ICAL DATA NOT 320 emergency push button IP rating IP20 Type of installation Surface or flush-mounted Material of impact cover Transparent plastic Operating voltage 24 V DC Current consumption 30 mA Number of cores … Number of relays … Visual operating state display yes Sabotage contact yes Contact rating 30 V / … A Temperature range -10 °C ... +50 °C 49 50 GEZE EMERGENCY EXIT SYSTEMS | Individual components NOT … 20 A P E ME R G E N CY P U S H B U T TO N Areas of application – Mains voltage can be switched off in the case of an emergency and during maintenance work – Indirect activation of GEZE emergency exit system door control units – Opening of automatic doors in case of an emergency – Surface-mounted installation for simple installation without a lot of installation effort – Outer areas due to high IP rating Product features – LED lighting for better visibility, even in the dark – Contact system consists of one normally closed contact and one normally opened contact – A second normally closed contact is available as an accessory – Robust plastic housing protects the emergency push button reliably from mechanical effects TECHN ICAL DATA NOT 220 AP emergency push button Dimensions 94 x 94 x 122 mm IP rating IP65 Type of installation surface-mounted Operating voltage 24 V DC Current consumption 15 mA Number of outputs … Temperature range -25 °C ... +70 °C NOT … 20 U P E ME RG E N CY P U S H B U T TO N Areas of application – Mains voltage can be switched off in case of an emergency – Mains voltage can be switched off in case of maintenance work – Indirect activation of GEZE emergency exit system door control units – Opening of automatic doors in case of an emergency – Flush-mounted installation makes almost flush integration possible with a low installation height Product features – LED lighting for better visibility – Contact system consists of one normally closed contact and one normally opened contact – A second normally closed contact is available as an accessory TECHN ICAL DATA NOT 220 UP emergency push button IP rating … x … x 98 mm Type of installation IP20 Type of installation flush-mounted Operating voltage 24 V DC Current consumption 15 mA Number of outputs … Temperature range -25 °C ... +70 °C Individual components | GEZE EMERGENCY EXIT SYSTEMS OR D E R IN FORM AT I O N Designation Version ID no. NOT 320 UP emergency push button without frame surface-mounted 136571 NOT 320 AP emergency push button with surface mounted cap Jung AS 500 and … x frame flush-mounted 137967 NOT 220 AP emergency push button surface-mounted 210203 NOT 220 UP emergency push button flush-mounted 210204 51 52 GEZE EMERGENCY EXIT SYSTEMS | Individual components Emergency exit signs FWS 320 B E ME R G E N CY E X I T SI G N E N … 3 637 Areas of application – Doors along escape and rescue routes – Illumination of the emergency exit sign in an emergency exit system door control unit for better visibility Product features – Flat design for flush-mounted and surface-mounted installation – Energy-efficient LED technology – With ribbon cable for convenient connection to the emergency exit system door control unit – Designed for installation in 55-type flush-mounted ranges TECHN ICA L DATA FWS 320 B emergency exit sign EN 13637 Dimensions 55 x 10 x 55 mm Type of installation Flush-mounted installation Material Plastic Operating voltage 24 V DC Current consumption 10 mA EMER GE N CY P U S H B U T TO N N OT I C E SI G N EN … 3 637 Areas of application – Doors along escape and rescue routes Product features – Self-adhesive TECHN ICAL DATA Emergency push button notice sign EN 13637 Dimensions 94 x 94 mm Colour green (RAL 6032) ORD E R IN FOR MAT I O N Designation Version ID no. FWS 320 B emergency exit sign EN 13637 illuminated with ribbon cable for installation on TZ 320 / SCT 320 green 193554 Emergency push button notice sign EN 13637 self-adhesive, dimensions: 94 x 94 mm green 193993 Individual components | GEZE EMERGENCY EXIT SYSTEMS Power supply NT … A-2 … V U P P OW E R SU P P LY Areas of application – Flush-mounted installation of the power supply – For the supply of 24 V drives and control units Product features – Compact power supply TEC HN ICAL DATA NT … A-24 V UP power supply (151426) Dimensions (W x H x D) 54 x 54 x 32 mm Output voltage 24 V DC Output current (max.) … A POW E R S U P PLY … 4 V D C ( N T 1. … A-2 … V HS) Areas of application – For installation on top hat rails – For the supply of 24 V drives and control units Product features – Quick and easy installation – Powerful power supply with small dimensions TEC HN ICAL DATA NT … A-24 V HS (151425) Dimensions (W x H x D) 35 x 90 x 58 mm Output voltage 24 V DC Output current (max.) … A Division units … division units 53 54 GEZE EMERGENCY EXIT SYSTEMS | Individual components POW E R S U P PLY … 4 V D C ( N T … . … A-2 … V H S) Areas of application – For installation on top hat rails – For the supply of 24 V drives and control units Product features – Quick and easy installation – Powerful power supply with small dimensions T ECH N ICAL DATA NT … A-24 V HS (151424) Dimensions (W x H x D) 52 x 90 x 58 mm Output voltage 24 V DC Output current (max.) … A Division units … division units POWE R S U P PLY … 4 V D C ( N T 6. 25 A-2 … V HS) Areas of application – For installation on top hat rails – For the supply of 24 V drives and control units Product features – Quick and easy installation – Powerful power supply with small dimensions TECHN ICAL DATA NT … A-24 V HS (192113) Dimensions (W x H x D) 72 x 95 x … mm Output voltage 24 V DC Output current (max.) … A Division units … division units Individual components | GEZE EMERGENCY EXIT SYSTEMS ST E P-U PS U N I N T E R R U P T I B LE P OW E R SUPPLY Areas of application – For installation on top hat rails – Approved for use with GEZE emergency exit system door control units Product features – Lithium-ion technology ensures low battery maintenance and a long service life – Integrated battery module enables compact design and space-saving top hat rail – Battery module installed without tools for easy replacement – Automatic, cyclical battery quality testing guarantees reliable operation and promptly signals when a battery needs to be replaced – Deep discharge protection protects the battery against damage, even under high loads – Alarm status is displayed visually on the device and can be transmitted via contact – Charge status is displayed visually on the device and can be transmitted via contact – Battery status is displayed visually on the device and can be transmitted via contact – Adjustable buffer time allows for individual adjustment to fit any application TEC HN ICAL DATA Phoenix Contact UPS 24 V DC, 46 WH (193212) Dimensions (W x H x D) 108 x 90 x 71 mm Output voltage 24 V DC Output current (max.) 3A Division units … division units OR D E R IN FOR M AT I O N Designation Version ID no. NT … A-24 V UP power supply black 151426 NT 24- … A - 24 V DC power supply grey 078401 NT … A-24 V HS power supply black 151425 NT … A-24 V HS power supply black 151424 NT … A-24 V HS power supply grey 192113 STEP-UPS uninterruptible power supply grey 193212 55 56 GEZE EMERGENCY EXIT SYSTEMS | Individual components Indicator lamps and signal horns SLE … 20 U P IN D ICATO R L A M P, G R E E N Areas of application – Increases safety even in large rooms – Approved for use with GEZE emergency exit system door control units – Designed for installation in 55-type flush-mounted ranges Product features – Warning light for reinforcing an optical alarm signal TECHN ICAL DATA SLE 220 UP indicator lamp, green Reflector colour green Operating voltage 24 V DC Current consumption 18 mA Switch programme Jung AS 500, alpine white SLE … 20 U P IN D ICATO R L A M P, R E D Areas of application – Increases safety even in large rooms – Approved for use with GEZE emergency exit system door control units – Designed for installation in 55-type flush-mounted ranges Product features – Warning light for reinforcing an optical alarm signal TECHN ICAL DATA SLE 220 UP indicator lamp, red Reflector colour red Operating voltage 24 V DC Current consumption 18 mA Switch programme Jung AS 500, alpine white Individual components | GEZE EMERGENCY EXIT SYSTEMS SLE 220 IN D ICATO R L A M P SU R FACE- M O UN TED Areas of application – Increases safety even in large rooms – Approved for use with GEZE emergency exit system door control units Product features – Warning light for reinforcing an optical alarm signal – Surface-mounted installation for simple installation without a lot of installation effort TEC HN ICA L DATA SLE 220 indicator lamp surface-mounted Dimensions (W x H x D) 61 x 61 x 74 mm Reflector colour red Operating voltage 24 V DC Current consumption 85 mA / 24 V Switch programme Jung AS 500, alpine white IP rating IP20 FLAS HLIGHT Areas of application – Increases safety even in door situations that are poorly visible – Approved for use with GEZE emergency exit system door control units – In humid environments due to high IP rating Product features – Surface-mounted installation for simple installation without a lot of installation effort – Sturdy, maintenance-free and fail-safe design due to the reflector’s polycarbonate housing – Xenon tubes for high visibility performance TEC HN ICA L DATA Flashlight Dimensions (Ø x H) 93 x 72 mm Reflector colour red Flashing frequency … Hz, ± 20 % Operating voltage 20-30 VDC Current consumption 90 mA IP rating IP54 57 58 GEZE EMERGENCY EXIT SYSTEMS | Individual components SIGN AL HOR N Areas of application – Increases safety even in door situations that are poorly visible – Approved for use with GEZE emergency exit system door control units – In humid environments due to high IP rating – Surface-mounted installation for simple installation without a lot of installation effort Product features – Controllable volume to make every application situation possible – 26 settings for signal tone TECHN ICAL DATA Signal horn Dimensions (Ø x H) 111 x … mm Reflector colour red Signal sound 26 settings Volume adjustable between 74 and 94 dB Operating voltage 10-28 VDC Current consumption 16 mA IP rating IP54 MU LTIFU N CTION A L SI R E N Areas of application – Increases safety even in large rooms – Approved for use with GEZE emergency exit system door control units – In humid environments due to high IP rating – Designed for installation in 55-type flush-mounted ranges – Can be mounted in flush-mounted sockets … mm deep Product features – Controllable volume to make every application situation possible – 28 settings for signal tone TECHN ICAL DATA Multifunctional siren Volume 20 - 107 dB/A (in … m) Signal sound Choice of 28 tones Operating voltage 10 - 28 V DC Current consumption 10 mA IP rating IP54 Installation flush-mounted sockets … mm deep Switch programme Jung AS 500, alpine white O RDE R IN FOR MAT I O N Designation Version ID no. SLE 220 indicator lamp flush-mounted green red 115936 115934 SLE 220 indicator lamp surface-mounted red 020866 Flashlight red 199465 Signal horn white 199469 Multifunctional siren alpine white 199471 Individual components | GEZE EMERGENCY EXIT SYSTEMS Synchronising unit ST … 20 S E RV IC E T E R M I N A L Areas of application – Emergency exit system door control units – Motor locks – Building automation components – Automatic door drives – Automatic window drives Product features – IR interface for the wireless parameter setting of emergency exit system door control units – … AAA batteries for wireless operation – Wired parameter setting via RS 485 bus – Voltage supply via cable in the case of wired operation – Four-line display and slim user interface for simple operation TEC HN ICAL DATA ST 220 service terminal Dimensions 80 x 125 x 37 mm IP rating IP40 O R D E R IN FOR M AT I O N Designation ID no. 087261 ST 220 service terminal Parameter setting and diagnosis for TZ 320, automatic sliding and swing door systems from DCU software … and IQ windowdrive, battery operation with … x AA cells (not supplied by GEZE), plain text display on illuminated display, membrane keyboard for operation 59 60 61 AC C ESS C O N T RO L A N D SA FE T Y Operating elements Locked safely – and yet open in emergencies. Finally, emergency exit electric strikes must also be operated reliably, which is the purpose of the range of operating elements. If your building possesses several emergency exits, you can control and manage them. Another intelligent product is the GEZE Cockpit, our building automation system, which networks door and window technology – and increases safety even more. 62 GEZE EMERGENCY EXIT SYSTEMS | Operating elements myGEZE Control connectivity platform Controller system as maximum system expansion with GEZE CAN bus, I/O technology and KNX to connect all GEZE products and third-party products. SYSTE M C O N S I ST I N G O F Basic device 10x 8-channel digital input terminal Potential distribution terminals 24 V DC Power supply terminal 10x output terminals 2-channel-relay 10x output terminals 4-channel-relay 5x CAN-master terminal + CAN-connector E-bus coupler 2x terminal KNX/EIB Bus end terminal AR E AS OF A P P L I CAT I O N BACnet IP integration in building management systems Networking of GEZE products that can be connected with CAN bus technology Networking of non BUS capable components via digital input and output terminals Networking of KNX capable GEZE window drives in the building management system Products suitable for emergency exit systems: TZ 320, TZ 321 and TZ 322 Products suitable for automatic door drives: Slimdrive, Powerturn, TSA 325 NT and Revo.PRIME Products suitable for smoke and heat extraction systems: MBZ 300 in different versions Products suitable for window systems: Slimchain, Powerchain, F 1200+ and locking systems For products with I/O technology like GEZE hold-open systems and third-party products Operating elements | GEZE EMERGENCY EXIT SYSTEMS P R OD U CT F E AT U R ES System is also available without CAN master terminals and digital input and output terminals Maximum system expansion for one control unit, which allows for the connection of up to 200 product systems from the entire product portfolio Comprehensive, project-specific configuration according to user specifications possible (system designation, comment texts, status texts) Time function and grouped switching commands configurable via scene applications BACnet alarm concept integrated, can be adjusted to customer-specific requirements PRODUCT FEATURES myGEZE Control with GEZE CAN bus, I/O technology and KNX Controller system to connect GEZE CAN products and non bus-capable components as well as KNX/EIB components myGEZE Control with GEZE CAN bus and I/O technology k Controller system to connect GEZE CAN products and non bus-capable components to the GEZE building system myGEZE Control with GEZE CAN bus, Control unit system for smaller applications to connect the GEZE CAN products over multiple bus lines BASIC DEVICE myGEZE Control basic device Powerful embedded PC for top hat rail mounting with integrated BACnet communication TERMINALS myGEZE Control CAN master terminal Master in terminal system for integration of the GEZE CAN devices over multiple bus lines myGEZE Control 8-channel digital input terminal Digital input terminal with eight inputs to detect binary control signals from the process level myGEZE Control output terminal 2-channel relay Digital output terminal with two potential-free relay outputs and one change-over contact for each myGEZE Control output terminal 4-channel relay Digital output terminal with four potential-free relay outputs and one single contact for each myGEZE Control potential distribution terminal 24 V DC Potential distribution provides 16 terminal points with a 24 V DC potential myGEZE Control potential distribution terminal … V DC Potential distribution provides 16 terminal points with a … V DC potential myGEZE Control power supply terminal To refresh the E-bus via data exchange between the basic controller and terminals myGEZE Control terminal KNX/EIB EIB/KNX bus terminal for connection to the KNX/EIB network myGEZE Control bus end terminal For data exchange between the bus coupler and bus terminal COUPLERS myGEZE Control E-bus coupler Connects terminal system and serves to install detached coupling stations (distribution box) CONNECTORS myGEZE Control CAN connector Connector in the housing for use with the myGEZE Control CAN master terminal COVERS myGEZE Control bus end cover To cover the E-bus contacts 63 64 GEZE EMERGENCY EXIT SYSTEMS | Operating elements myGEZE Visu Building management software for visualisation, operation, control and monitoring of connected GEZE product systems AR E AS OF A P P L I CAT I O N Operation of a building management system for door, window and safety technology of GEZE product systems and competitors Visualisation, operation and monitoring of connected GEZE products Use of standardised workflows to release incidents Alarm concepts for forwarding incidents in modern facility management systems PR OD U CT F E AT U R ES Visualisation system with modular and flexible authorisation concept Visualisation, operation, and monitoring of connected GEZE product systems Location option for devices on a customer-specific building plan Pre-defined, adaptable alarm concept for multi-stage processing of alarms, faults and messages Application for using e-mail notification service Multi-station capable operating system Activation of further functions via license model Simple and intuitive interface set-up and configuration Optimised for connection to myGEZE Control systems Parallel operation with any building management system possible Operating elements | GEZE EMERGENCY EXIT SYSTEMS Accessories IO 420 E X TE N S I O N M O D U LE Area of application – Module to expand the digital inputs and outputs on the TZ 320 Product features – Plastic top-hat rail housing for installation in the control cabinet or suspended ceiling – Four integrated relays, each with a potential-free changeover contact for carrying out switching functions – Four integrated inputs for the release of switching functions and/or the placement of messages – Connection between the interface modules via RS 485 interface in line topology TEC HN ICA L DATA IO 420 extension module Dimensions 107 x 111 x 59 mm Service temperature -20 °C...+80 °C Operating voltage 24 V DC LEDs … (red), … (yellow), … (red), … (green), … (green), … (yellow), in (green), out (red) Interfaces GEZE bus … inputs … outputs DIP switch GEZE bus terminating resistor 120 Ohm Micro SD card FAT16/32 file format for setting parameters and changing settings via PC Reset button to reset factory settings 65 66 GEZE EMERGENCY EXIT SYSTEMS | Operating elements BUS R E P E ATE R Areas of application – Networked GEZE emergency exit systems Product features – For extending the bus length by a further 900 m – For installation on standard carrier rails – Several repeaters and carrier rail connectors are needed for implementing star and tree structures TECHN ICA L DATA BUS repeater Dimensions … x 66 x … mm IP rating IP20 Type of installation Top hat rail mounting Supply voltage 10 - 32 V DC Current consumption 80 mA (at 24 V DC) O RDE R IN FOR MAT I O N Designation ID no. CAN interface galvanically isolated CAN extension module for automatic sliding door, revolving door and swing door drives 119952 BUS repeater 142499 Contents | GEZE EMERGENCY EXIT SYSTEMS 67 We are GEZE. For liveable buildings GEZE stands for innovation, high quality and comprehensive support of building technologies. From the initial idea, planning and operational implementation with standard products to customised system solutions and individual service and maintenance plans. We offer an extensive product range of door, window and safety technology products and are a major driving force behind the digital networking of building automation. GEZE GmbH Reinhold-Vöster-Strasse 21 – 29 71229 Leonberg Germany Phone: +49 7152 203 … Fax: +49 7152 203 310 E-Mail: info.de@geze.com www.geze.com 2024_09 ID no. 132408 EN Subject to change without notice